Dacor EF36LNBSS Скачать руководство пользователя страница 18

16

Product Data Sheets

Base Grille Water Filtration System (Water Filter)

Model WF-LC400V/LC400V Capacity 400 Gallons (1514 Liters)

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the 
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water 
leaving the system, as specified in ANSI/NSF 42/53.

Substance Reduction 
Aesthetic Effects

NSF Reduction 
Requirements

Average  
Influent

Influent Challenge 
Concentration

Maximum 
Effluent

Average 
Effluent

Minimum % 
Reduction

Average % 
Reduction

Chlorine Taste/Odor  
Particulate Class 1*

≥50% 

≥85%

2.1 mg/L 
5,366,667/mL

2.0 mg/L ± 10%
At least 10,000
particles/mL

0.06 mg/L
4,100/mL** 

0.05 mg/L
2,300/mL

97.1%
99.3%

97.6%
99.9%

Contaminant 
Reduction

NSF Reduction 
Requirements

Average  
Influent

Influent Challenge 
Concentration

Maximum 
Effluent

Average 
Effluent

Minimum % 
Reduction

Average % 
Reduction

Lead: @ pH 6.5
Lead: @ pH 8.5

0.01mg/L
0.01mg/L

0.152 mg/L†
0.143 mg/L†

0.15 mg/L ± 10%
0.15 mg/L ± 10%

0.001 mg/L
0.001 mg/L

0.001 mg/L
0.001 mg/L

99.34%
99.30%

99.34%
99.30%

Mercury: @ pH 6.5
Mercury: @ pH 8.5

0.002 mg/L
0.002 mg/L

0.0061 mg/L
0.0057 mg/L

0.006 mg/L ± 10%
0.0058 mg/L ± 10%

0.0004 mg/L
0.0008 mg/L

0.0003 mg/L
0.00051 mg/L

93.5%
85.8%

96.7%
91.2%

Benzene

0.005 mg/L

0.0162 mg/L

0.015 ± 10%

0.0005 mg/L

0.001 mg/L

96.3%

96.3%

p-dichlorobenzene

0.075 mg/L

0.220 mg/L

0.225 ± 10%

0.0005 mg/L

0.0005 mg/L

99.7%

99.7%

Toxaphene

0.003 mg/L

0.014 mg/L

0.015 ± 10%

0.0014 mg/L

0.001 mg/L

90%

92.96%

Atrazine

0.003 mg/L

0.0086 mg/L

0.009 mg/L ± 10%

0.0005 mg/L

0.0005 mg/L

94.25%

94.25%

2, 4-D

0.07 mg/L

0.197 mg/L

0.210 ± 10%

0.058 mg/L

0.0137 mg/L

70.6%

93.06%

Asbestos

99%

26 x 107

107 to 108 fibers/L††

0.18 x 107 mg/L 0.18 x 107 mg/L

99.93%

99.93%

Cysts‡
Turbidity

99.95%
0.5 NTU

111,000/mL
11.00 NTU

50,000/L min.
11 ± 1 NTU

1 mg/L
0.40 NTU

1 mg/L
0.35 NTU

99.99%
96.4%

99.99%
96.8%

* Class I particle size: >0.5 to <1 um  
** Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. 
† These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. 
†† Fibers greater than 10 um in length 
‡ Based on the use of Cryptosporidium parvum oocysts 
® NSF is a registered trademark of NSF International.

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F 
(17.2°C).

Application Guidelines/Water Supply Parameters

Water Supply 

 

City or Well

Water Pressure   

30 - 120 psi (207 - 827 kPa)

Water Temperature 

33° - 100°F (0.6° - 37.8°C) 

Service Flow Rate  

0.5 GPM (1.89 L/min.) @ 60 psi.

Tested and certified by NSF International against ANSI/NSF Standard 42 for 
the reduction of Chlorine Taste and Odor, Particulate Class I*; and against 
ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, 
Toxaphene, p-dichlorobenzene, 2, 4-D, Cysts, Turbidity and Asbestos.

It is essential that operational, maintenance, and filter 

 

„

replacement requirements be carried out for the product to 
perform as advertised.

The filter monitor system measures the amount of water that 

 

„

passes through the filter and alerts you to replace the filter. 
When 90% of the filter’s rated life is used, the filter indicator 
light changes from green to yellow. When 100% of the filter’s 
rated life is used, the filter indicator light changes from yellow 
to red, and it is recommended that you replace the filter. Use 
replacement cartridge AFF5. Visit www.everythingdacor.com.

The product is for cold water use only.

 

„

Do not use with water that is microbiologically unsafe or of 

 

„

unknown quality without adequate disinfection before or after 
the system. Systems certified for cyst reduction may be used 
on disinfected waters that may contain filterable cysts.

Содержание EF36LNBSS

Страница 1: ...or Safety 1 Important Information 2 Model Identification 2 Before Use 3 Refrigerator Operation 3 11 Care and Cleaning 12 13 Troubleshooting 14 15 Product Data Sheets 16 Warranty and Service 17 Notes 1...

Страница 2: ...2008 Dacor all rights reserved...

Страница 3: ...ead and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbo...

Страница 4: ...refrigerator ready These numbers are found on a serial number label located on the right side of the refrigerator liner Record these numbers on this page for easy access Model number _________________...

Страница 5: ...eed to turn the power to your refrigerator on or off you must remove the top grille assembly to access the power switch Turn the power to the refrigerator off when cleaning your refrigerator or changi...

Страница 6: ...kPa Check to see whether the sediment filter in the reverse osmosis system is blocked Replace the filter if necessary Allow the storage tank on the reverse osmosis system to refill after heavy usage...

Страница 7: ...ed airflow will be obstructed and temperature and moisture problems may occur IMPORTANT Because air circulates between both sections any odors formed in one section will transfer to the other You must...

Страница 8: ...s manually turned off NOTE The refrigerator temperature display will remain at 34 F 1 C and the freezer temperature display will remain at 5 F 21 C while the Max Cool feature is on After 24 hours the...

Страница 9: ...remain unchanged On some models the Holiday Mode feature doesn t disable the ice and water dispenser For these models the lock button can be used to disable the ice and water functions but depressing...

Страница 10: ...ake sure the water softener is operating properly and is well maintained It is normal for the ice cubes to be attached at the corners They will break apart easily Do not store anything inside the ice...

Страница 11: ...ionally mold will develop on the surface of hard cheeses Swiss Cheddar Parmesan Discard moldy cheese Dairy Food Most dairy foods such as milk yogurt sour cream and cottage cheese have freshness dates...

Страница 12: ...containers Force as much air out of the packages as possible and be sure they are tightly sealed Trapped air can cause the food to dry out change color and develop an off flavor freezer burn Wrap fre...

Страница 13: ...refrigerator has an automatic ice maker 3 shut off the water supply to the ice maker Empty the ice bin 4 When you return from vacation press the 5 HOLIDAY key to return to normal operation If you choo...

Страница 14: ...contact with plastic parts such as the trim pieces dispenser covers or door gaskets If unintentional contact does occur clean the plastic part with a sponge and mild detergent in warm water Dry thorou...

Страница 15: ...o the new filter See 4 illustration in Step 2 With cap in the vertical position push the new water filter into 5 the base grille until it stops Rotate the cap clockwise to a horizontal position Flush...

Страница 16: ...80 of the time Under warmer conditions it will run even more Has a large amount of food just been added to the refrigerator Adding a large amount of food warms the refrigerator The motor normally will...

Страница 17: ...ur You may need to install a filter to remove the minerals Is there a water filter installed on the refrigerator Gray or dark discoloration in ice indicates that the water filtration system needs addi...

Страница 18: ...107 mg L 99 93 99 93 Cysts Turbidity 99 95 0 5 NTU 111 000 mL 11 00 NTU 50 000 L min 11 1 NTU 1 mg L 0 40 NTU 1 mg L 0 35 NTU 99 99 96 4 99 99 96 8 Class I particle size 0 5 to 1 um Test requirement i...

Страница 19: ...the product Dacor will pay for replacement parts to correct defects in materials and workmanship Note The full warranty and the limited warranties apply when the refrigerator is located in the United...

Страница 20: ...Dacor Phone 800 793 0093 FAX 626 403 3130 www Dacor com...

Отзывы: