Installation Instructions

Connect Water Supply (cont.)

Connecting to Refrigerator

Parts Supplied:

 ¼” to ¼” (6.4 mm to 6.4 mm) male to male 

coupling.

NOTE:

 The flexible codes approved water supply line can connect 

to the supply valve through the floor or through the side cabinets, 
as indicated by the gray boxes above.

1.  Unplug the refrigerator or disconnect power.

2.  Connect the 7 ft (2.1 m) minimum flexible codes approved 

water tube to the water supply valve.

3.  Flush the main water supply line to remove particles and air in 

the water line. Allow enough flow so that the water becomes 
clear.

4.  Tape the water supply line to the floor, 7” (17.8 cm) from the 

left side of the refrigerator. Tape along the length of the tubing, 
which will allow it to pass beneath the refrigerator without 
interference.

NOTE:

 Allow a minimum of 26” (66.0 cm) of flexible codes 

approved water supply line to be loose at the front of the 
refrigerator for connecting to the household water line.

5.  Connect the water supply line to the refrigerator.

NOTE:

 If the main water shutoff valve is behind the 

refrigerator, a secondary water shutoff valve may be installed 
in line with the water supply line at the front of the product.

6.  Turn on the water valve and check all connections for leaks.

Plug in Refrigerator

1.  Set the control switch at top of cabinet to the 

OFF

 position.

2.  Plug the refrigerator into a grounded 3 prong outlet.

Move to Final Location

IMPORTANT

: To avoid floor damage, make sure the levelers are 

raised (not touching floor) and refrigerator is on rollers before 
moving.

1.  Place the top of the cardboard carton or plywood under 

refrigerator. Remove dolly.

2.  Do not remove the film on the outside.

3.  Move the refrigerator straight back and evenly into the 

opening. Be sure the refrigerator side trims do not interfere 
with the door opening. Also, be sure that the water tubing is 
not kinked and the power cord is on top of the refrigerator.

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, 
fire, or electrical shock.

WARNING

WARNING

Tip Over Hazard

Refrigerator is top heavy and tips easily when not 

completely installed. 
Keep doors taped closed until refrigerator is 

completely installed.
Use two or more people to move and install 

refrigerator.
Failure to do so can result in death or serious injury.

A

B

E

C

D

A.  Household water line 
B. Coupling 
C.  Bulb
D. Nut
E.  Refrigerator water  
 tubing

Possible water 

line locations

1” 

(2.5 cm)

7” 
(17.8 cm)

1” x 1” 

 (2.5 cm x 2.5 cm)

Содержание DYF42BIWS

Страница 1: ...Part No 107201 Rev A W10539432 Discovery Built In Refrigerator 42 and 48 Inch Models DYF42BIWS DYF48BIWS Installation Instructions...

Страница 2: ...S A and Canada Monday Friday 6 00 a m to 5 00 p m Pacific Time Web site www dacor com Dacor Distinctive Service repairs under warranty only Phone 800 793 0093 extension 2822 U S A and Canada Monday F...

Страница 3: ...ages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are v...

Страница 4: ...above the floor See Install Anti Tip Boards for more information NOTE A clearance of 2 1 3 cm must be maintained above the top grille in order for the top grille to be removed Tools and Parts IMPORTAN...

Страница 5: ...tallation Requirements Locate the refrigerator so that it may easily be pulled out from the wall if service becomes necessary A grounded 3 prong electrical outlet should be placed as shown in the illu...

Страница 6: ...it must be at an angle so that the water line is not kinked when the refrigerator is pushed into its final position If the water shutoff valve is not in the cabinets the plumbing for the water line c...

Страница 7: ...ew Model Width A DYF42BIWS 41 104 1 cm DYF48BIWS 47 119 4 cm Installation Requirements Front View The width dimensions were measured from trim edge to trim edge The height dimensions are shown with le...

Страница 8: ...st permit both doors to open to a minimum of 90 Allow 4 11 4 cm minimum space between the side of the refrigerator and a corner wall To adjust the door swing see Adjust Doors Model DYF42BIWS Installat...

Страница 9: ...Side Trim Inset Installation Dimensions 1 Measure the distance from point A as shown to the back wall Add 7 32 5 6 mm to this measurement to allow the side panel to fit into the trim 2 If the panel i...

Страница 10: ...m Installation Instructions 1 Grasp both ends of the top grille 2 Push the top grille straight up then pull straight out Lay the grille on a soft surface 3 Remove the six screws attaching each cabinet...

Страница 11: ...the Water Supply Requirements see Connecting to Refrigerator 1 Unplug the refrigerator or disconnect power 2 Turn OFF the main water supply Turn ON the nearest faucet long enough to clear the line of...

Страница 12: ...6 Turn on the water valve and check all connections for leaks Plug in Refrigerator 1 Set the control switch at top of cabinet to the OFF position 2 Plug the refrigerator into a grounded 3 prong outlet...

Страница 13: ...Nm of torque to the leveling bolts The leveling legs can be extended to a maximum of 1 3 2 cm below the rollers Level and Align Refrigerator IMPORTANT All four leveling legs must contact the floor to...

Страница 14: ...t head mounting screws and the two hex head mounting screws 2 Adjust the top hinge of either door to align it with the other door or the refrigerator trim 3 Tighten the four Torx 27 flat head mounting...

Страница 15: ...e routed side panel into the trim piece 2 Nail the rear edge of the panel to the support board Install Base Grille There are two pieces to the base grille to allow for a custom fit the base grille its...

Страница 16: ...he cap is in the horizontal position 2 Use a sturdy container to depress and hold the water dispenser lever for 5 seconds then release it for 5 seconds Repeat until water begins to flow Once water beg...

Страница 17: ......

Страница 18: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: