Installation requirements
English
20
Installation requirements
Maintain the following minimum clearance dimensions
B
A
30” (762 mm)
min.
1
13”
(33.0 mm)
max.
3
Grate level
Cutout for
utilitty access
Top of
finishied
counter
Note 2
18”
(457 mm)
min.
1, 3
1
Vertical to combustible surface from
rangetop grate level; if installing an
overhead vent hood, also check the
hood specifications for minimum
required clearances.
2
See Cabinet/Countertop Dimensions -
Top View.
3
This specification not applicable
for cabinets more than a horizontal
distance of 10” (25.4 cm) from the
edge of the rangetop.
Rangetop
DTT36M974L*
DTT48M976L*
A
36" (91.41 cm)
48" (121.9 cm)
B
36" (91.41 cm)*
42" (106.7 cm)**
48" (121.9 cm)*
54" (137.2 cm)**
* Minimum
** Recommended
A: Rangetop cutout
B: Range hood cutout
NOTE
All vertical clearances must be maintained for a minimum of 18” (457 mm) above the
cooking surface.