Installation Specifications
WARNING
•
This appliance must be installed and electrically
grounded in conformance to local codes.
•
In the absence of local codes, the appliance
installation must conform with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 and the National
Electrical Code, ANSI/NFPA 70.
•
Installation of this range in a manufactured (mobile)
home must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part
3280 [formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD (Part 280)] or
with local codes where applicable.
•
This range is not designed for installation in a
recreational vehicle.
•
Do not obstruct flow of combustion and ventilation air.
•
To prevent an electric shock hazard, the power supply
must meet the specifications stated below. It is the
owner’s responsibility to make sure that the electrical
service meets electrical requirements and that the
electrical outlet has been properly installed by a
licensed electrician.
Electrical Power Supply Requirements
•
The range is supplied with a factory installed, 6 foot
long, power cord with a three-prong grounding plug.
It is connected to the chassis at the rear of the range.
It must be connected to a dedicated, grounded three-
prong electrical outlet installed by a licensed electrician.
•
The correct voltage, frequency and amperage must
be supplied to the electrical outlet according to the
product data label (see inside cover for location). The
Electrical Supply Requirements
provided below are
for reference.
Electrical Circuit
Required
Total Connected Load
120 Vac 60 Hz,
15 Amp.
0.5 kW
(4.0 Amp.)
Electrical Supply Requirements
IMPORTANT:
The above information is for reference only.
If the information above differs from the information on the
product data label on the appliance, use the information on
the label.
Gas Supply Requirements
•
Be certain that the range being installed is correct for
the gas service being provided (natural gas or LP gas).
•
An external manual shut-off valve must be installed
between the gas inlet and the range for the purpose of
turning on or shutting off gas to the appliance.
•
The range comes from the factory with the regulator
installed. Use only the installed regulator.
•
The gas inlet on the regulator accommodates a
1/2” NPT gas line connection. The range can also
accommodate a 3/4” NPT gas line connection by
removing the 1/2” to 3/4” adapter on the regulator inlet.
Gas
Type
Manifold
Pressure*
(WC)
Min. Gas Supply
Pressure (WC)
Max. Input
Pressure
Natural
5”
6”
1/2 psi
LP
10”
11”
1/2 psi
Gas Supply Requirements
* The gas supply pressure for testing the regulator setting
shall be at least 1 inch water column (249 Pa) above the
specified manifold pressure.
IMPORTANT:
The information above is for reference only. If
the above data does not agree with the product data label,
use the data on the label. See the inside cover for location.
The gas connection is located on the back of the unit as
shown below.
12 1/4”
(31.1 cm)
to
14 1/4”
(36.2 cm)
4 1/4”
(10.8 cm)
Power
cord
Gas
connection