Electrical requirements
WARNING
•
Failure to follow these instructions can result in death, fire, or electrical shock.
•
It is the owner’s responsibility to make sure that the electrical service meets electrical
requirements and that the electrical outlet has been properly installed by a licensed electrician
to reduce the risk of fire, electric shock, or personal injury.
All ranges
• Do not use an extension cord or adapter plug with this range.
• This range must be properly grounded.
• Check with a qualified electrician if you are in doubt as to whether your range
is properly
grounded.
• Do not modify the range power plug. If it does not fit the outlet, have a proper
outlet
installed by a qualified electrician.
• All wiring and grounding must comply with local codes or, in the absence of
local codes, with
the National Electrical Code, ANSI/NFPA No. 70 – Latest Revision (US), or the Canadian
Electrical Code CSA C22.1 – Latest Revisions and local codes.
• Wiring diagram is located on the back of the range. (Inside
envelope)
• The range’s electronic ignition system will not operate if the outlet is not
properly polarized.
• A dedicated circuit breaker is recommended.
• Use the chart below to determine the minimum recommended dedicated
circuit protection.
KW Rating (240 V)
Recommended Circuit Size (Dedicated)
36” Pro Range: 7.3 KW - 9.6 KW
40 Amp
48” Pro Range: 9.7 KW - 12.0 KW
50 Amp