English
19
4-Wire Cable from Home Power Supply
IMPORTANT:
Use the 4-wire cable from home power supply in:
•
the US where local codes do not allow grounding through neutral
•
New Branch circuit installations (1996 NEC)
•
mobile homes and recreational vehicles
•
new construction
•
Canada.
A
E
B
G
H
I
C
D
F
A.
Cable from home power supply
B.
Black wires (normally L1)
C.
Red wires (normally L2)
D.
4-wire flexible conduit from oven
E.
Junction box
F.
White wires (normally N-neutral)
G.
UL
-
listed wire connectors
H.
Green wires (normally G-ground)
I.
UL listed or CSA approved conduit connector
NOTE:
Connect all wires with UL-listed wire
connectors (G).
1.
Connect the 2 black wires (B).
2.
Connect the 2 red wires (C).
3.
Untwist
the
white wire from
the
green
(or bare) ground wire from the oven.
4.
Connect the 2 white wires (F).
5.
Connect the green (bare) ground wire
(H)
from the oven cable to the green
(bare) ground wire (in the junction
box).
6.
Install
the
junction
-
box cover.
Installation instructions