background image

9

Verifying Package Contents

•  Hold-down brackets (2)
•  Gas pressure regulator (1)
•  Grates: DTCT304G (2), DTCT365G (3) DTCT466G (3)
•  Burner sets: DTCT304G (4), DTCT365G (5),   

 

    

DTCT466G 

(6)

•  Stainless steel cleaner (1)
If any parts are missing, see the 

Replacement Parts 

list on 

page 12 for ordering information.

Installing the Cooktop

 WARNING

•  Verify that the power supply meets the specifications 

on page 4 before proceeding.

•  To prevent damage to the gas pressure regulator, 

install it only after the cooktop is mounted in its per-

manent position.

 IMPORTANT

•  Do not over-tighten the hold-down bolts. Over 

tightening the hold-down bolts may result in improper 

operation of the dual gas burners.

•  Do not use a hardening compound or caulk to 

permanently seal the cooktop into place. The cooktop 

must be readily removable if service is required. 

Removing the sealing to service the unit will be 

performed at the customer’s expense.

If the cooktop will be used with a downdraft vent, first 

install the vent according to its installation instruc-

tions.

1.  Lower the cooktop into the cutout and center it. 
2.  Secure the cooktop to the countertop using the hold-

down brackets as shown.

Installation Instructions

Underneath the Cooktop

Connecting the Gas Line

 WARNING

•  Verify that the gas supply meets specifications before 

connection. See page 4.

•  Do not install or use the cooktop without the included 

gas regulator installed.

•  Ensure that the arrow on the regulator points toward 

the direction of the gas flow (toward the cooktop).

•  Do not apply excessive pressure when tightening gas 

connections and fittings.

•  Do not use Teflon tape or plumber’s putty on flexible 

gas line connections.

•  Test the gas lines for leaks as instructed before use. 

Do not use a flame to check for leaks. 

•  The maximum gas supply pressure to the regulator 

must never exceed 1/2 pounds per square inch (psi) 

or 3.5 kPa.

•  The cooktop and shut-off valve must be disconnected 

from the gas supply piping system during any pres-

sure testing exceeding 1/2 psi (3.5 kPa).

•  The cooktop must be isolated from the gas supply 

piping system by closing the shut-off valve to the 

cooktop during any gas supply piping system pres-

sure testing equal to or less than 1/2 psi (3.5 kPa).

•  For LP gas installations, the LP gas tank must have 

its own high-pressure regulator in addition to the 

pressure regulator supplied with the cooktop.

1.  Attach the gas pressure regulator (included) to the gas 

inlet on the cooktop. 

•  When working in tight space constraints, the regulator 

can be installed anywhere between the cooktop and 

gas supply/shut-off valve.

•  For best performance, attach the regulator as close as 

possible to the cooktop. This will minimize gas pressure 

loss.

2.  Connect regulator to the gas supply/shut-off valve with 

a minimum 1/2” flexible gas line (not included). 

3.  Check for gas leaks:

◊ 

Turn all cooktop control valves to OFF.

◊ 

Make a soap and water solution or use a gas leak 

detector and check all lines and connections for 

gas 

leaks. 

 

 

     

* Make sure the gas supply/shut-off valve is ON.

◊ 

Turn the gas supply/shut-off valve OFF.

Hold-down bracket 

mounting holes

Gas inlet

Содержание Distinctive DTCT304G

Страница 1: ...Installation Instructions Models DTCT304G DTCT365G DTCT466G Distinctive Gas Cooktop Part No 108856 Rev C...

Страница 2: ...or future reference and for the local electrical inspector s use NOTE Dacor is not responsible for service required to correct a faulty installation 2015 Dacor all rights reserved If You Need Help If...

Страница 3: ...so blocks air flow through the cooktop and may cause carbon monoxide poisoning Aluminum foil linings may also trap heat causing a fire hazard Keep all slots holes and passages clear of grease and grim...

Страница 4: ...shock serious injury or death when using your appliance follow basic safety precautions including the following Do not leave children alone or unattended in the area around the cooktop Do not allow ch...

Страница 5: ...in 53 3 cm 4 in 10 2 cm chassis height 36 in 91 4 cm 33 1 2 in 85 1 cm including raised embosses on sides of chassis 19 1 2 in 49 5 cm 21 in 53 3 cm 1 5 8 in 4 1 cm bottom of base to cooking surface...

Страница 6: ...ssis Bottom for the label location Units equipped for high altitude operation have an H at the end of the model number listed on the product data label Check your local building codes for the proper m...

Страница 7: ...electrical outlet must be placed so they do not interfere with the cooktop when it is installed If installing another appliance in the cabinet below allow for the routing of gas and power behind it Th...

Страница 8: ...04G with ERV3015 and PRV30 Square 3 8 in 1 0 cm 22 1 2 in 57 2 cm 27 3 4 in 68 6 cm NA NA NA DTCT304G with RV30 Square 5 8 in 1 6 cm 22 1 4 in 56 5 cm 27 3 4 in 68 6 cm NA NA NA DTCT365G without downd...

Страница 9: ...ear wall 1 7 8 in min 4 8 cm Side wall E C D H H G F 7 1 2 in 19 1 cm min to combustible side wall above countertop both sides Vertical combustible surface Rear wall 1 7 8 in min 4 8 cm Side wall 4 1...

Страница 10: ...ace Countertop Floor 5 8 in min 1 6 cm space needed behind downdraft vent chassis to clear stiffener 4 5 8 in 11 7 cm 9 7 8 in 25 1 cm with CABP3 blower installed RV Series Downdraft Check downdraft s...

Страница 11: ...rd the direction of the gas flow toward the cooktop Do not apply excessive pressure when tightening gas connections and fittings Do not use Teflon tape or plumber s putty on flexible gas line connecti...

Страница 12: ...ktop must be properly grounded at all times when electrical power is applied Prior to operating the cooktop carefully read the accompanying Use and Care Manual 1 Make sure all the cooktop burner contr...

Страница 13: ...proper operation been verified Has the warranty been activated on line or the warranty card filled out completely and mailed Verifying the Correct Setup Once the burner lights rotate the control knob...

Страница 14: ...ght front 86408 Burner cap right rear 86523BM Burner ring right rear 86407 DTCT365G Description Dacor Part Number Regulator 82540 Grate large 108850 Grate small 108851 Burner cap left front 72435BM Bu...

Страница 15: ...ams AFTER SERVICING VERIFY PROPER OPERATION 120V 60Hz POWER SUPPLY CAUSE IMPROPERAND DANGEROUS OPERATION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUTION LABELALLWIRES PRIORTO DISCONNECTION WIRING DI...

Страница 16: ...ams AFTER SERVICING VERIFY PROPER OPERATION 120V 60Hz POWER SUPPLY CAUSE IMPROPERAND DANGEROUS OPERATION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUTION LABELALLWIRES PRIORTO DISCONNECTION WIRING DI...

Страница 17: ...ams AFTER SERVICING VERIFY PROPER OPERATION 120V 60Hz POWER SUPPLY CAUSE IMPROPERAND DANGEROUS OPERATION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUTION LABELALLWIRES PRIORTO DISCONNECTION WIRING DI...

Страница 18: ...16 Notes...

Страница 19: ...17 Notes...

Страница 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: