5
Callout
Description
1
30” min. clearance from cooktop surface and bottom of unprotected wood or metal cabinet
2
Distance to combustible side wall (either side): 2 1/4” (5.7 cm) min. from edge of cooktop surface.
3
If the cooktop side of the upper cabinetry is more than 2 1/4” (5.7 cm) to the left/right of the cooktop edge, Specification 3 does not apply..
4
1 1/8” (2.9 cm) min. to combustible surface at rear; 3/4” (1.9 cm) min. to non-combustible surface at rear.
5
Ensure internal space allows proper under-cabinet ventilation for cooktop chassis. (See
Cooktop Clearance/Ventilation
, Pg. 3.)
Cabinet Cutout Dimensions
All tolerances: ±1/16 (±1.6 mm), unless otherwise stated
See the next page for flush- and downdraft-installation cutouts.
Cabinet Clearances
Model
A
B
DYTT305
30” (76.2 cm)
28 3/4” (73.0 cm)
DYTT365
36” (91.4 cm)
34 3/4” (88.3 cm)
INSTALLATION SPECIFICATIONS