15
Product Data Sheets
Application Guidelines/Water Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33° - 100°F (0.6° - 37.8°C)
Service Flow Rate
0.5 GPM (3.2 Lpm) @ 60 psi.
It is essential that operational, maintenance and filter
replacement requirements be carried out for the product to
perform as advertised.
Use replacement filter P2RFGG2, Dacor part # AFF6. Visit
www.everythingdacor.com or call 1-800-253-1302 (In Canada
call 1-800-807-6777).
When the water filter status display changes from GOOD to
ORDER FILTER, order a new filter. When the filter indicator
reads REPLACE FILTER, it is recommended that you replace
the filter.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
Refer to the
Warranty and Service
section for the
Manufacturer’s name, address and telephone number.
Refer to the
Warranty and Service
section for the
Manufacturer’s limited warranty.
Base Grille Water Filtration System
Model P2RFGG2/P2WG2L, P2WG2, P1WG2L, P1WG2
Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor
Particulate Class I
50% reduction
85% reduction
2.0182 mg/L
1333333 #/mL
2.0 mg/L ± 10%
At least 10,000 particles/mL
0.06 mg/L
6600 #/mL*
0.0536 mg/L
2325 #/mL
97.03
99.51
97.39
99.9
Contaminant
Reduction
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
0.010mg/L
0.010mg/L
0.1533 mg/L
0.1400 mg/L
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.0005 mg/L
0.0007 mg/L
0.0005 mg/L
0.0006 mg/L
99.67
99.50
99.29
99.14
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.0058 mg/L
0.0059 mg/L
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.0002 mg/L
0.0005 mg/L
0.0002 mg/L
0.0003 mg/L
96.54
91.57
96.25
82.72
Benzene
0.005 mg/L
0.0154 mg/L
0.015 ± 10%
0.0012 mg/L
0.0006 mg/L
92.22
96.88
O-Dichlorobenzene
0.6 mg/L
1.7571 mg/L
1.8 mg/L ± 10%
0.0250 mg/L
0.0066 mg/L
98.58
99.97
Toxaphene
0.003 mg/L
0.015 mg/L
0.015 ± 10%
0.001 mg/L
0.001 mg/L
93.33
92.77
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class I; and against NSF/ANSI Standard 53 for the reduction of Mercury,
Benzene, Toxaphene, O-dichlorobenzene, and Lead.
* Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
® NSF is a registered trademark of NSF International.
Manufactured for Whirlpool Corporation (Benton Harbor, MI) by Kemflo International (Pingtung, TW)