DIGITAL INDICATOR
550A
14
Ⅴ
. 5STEP
Please put span standard weight on the platform.(The weight is
1000kg at here)
Press
“
ENTER
”
key after stable of platform.
(NOTICE)If indicator is unmatched with load cell capacity or span standard
weight, indicator will display error message(Err A)
Ⅵ.6STEP
Indicator will display any constant value of span adjustment.
If the range of this constant value is between 0.5000
∼
1.50000,
All procedure of span adjustment is normal.
And then, press
“
ENTER
”
key for next procedure.
If you remember this constant value, you can adjust the span without
Standard weight by
“
F89
”
(Function number
“
F89
”
)at set-up mode.
(Please remember this constant value, full capacity and one digit for your
further calibration & reference)
Ⅶ.7STEP
The
“
END
”
message is display in 6 step, all span adjustment is end.
Press
“
ENTER
”
key after put down of span standard weight the platform.
The indicator will enter user
’
s weighing mode.
.
C_uP____
Down_
C_End.__
1.02476