![DACE Compact Скачать руководство пользователя страница 13](http://html2.mh-extra.com/html/dace/compact/compact_manual_3126668013.webp)
SETTING THE MOTOR DIRECTION
FOR A GATE CLOSING TO THE LEFT
FOR A GATE CLOSING TO THE RIGHT
BLUE WIRE
BLACK WIRE
BLUE WIRE
BLACK WIRE
Closing direction
Closing direction
It is important to set the motor direction
, as this will influence the programming of the motor and the security of the motor.
The motor is set to automatically close whenever the power is applied and the test button is pressed for the first time. If the
gate runs open when the test button is pressed during programming this means that the motor wires are incorrect. The motor
wires are the two wires that protrude from the electric motor and are connected to the main P.C.Board.
The other reason that the setting of the motor direction is important, is that the motor will automatically drive to the closed
position after a prolonged power failure, thus ensuring the gate will not stay in the open position.
The following diagrams show the correct wiring of the electric motor to the main P.C.Board. The motor wires are found protruding
from the motor, there are two wires, one wire is blue in colour the other wire is black in colour.
PROGRAMMING THE MOTOR
The motor must be programmed to the gate in order to operate correctly. Once the motor has been programmed to the gate, the
program is held in the memory on the microchip, there is no need to re-program the motor after the initial program.
It is important to note that the following points should be checked before the gate is programmed.
1.
Gear box is filled with the gearbox oil supplied.
2.
Motor is level.
3.
Rack is secure to the gate and engaged with the pinion gear.
4.
The gate has adequate end stops. (
DO NOT
automate a gate without end stops.)
5.
The gate runs freely and does not jam at
ANY
part of travel.
6.
The magnet is mounted correctly.
Continued overleaf
Содержание Compact