background image

5

DESCRIPTION OF EQUIPMENT

General Description

Compact handpiece, ergonomic design, body made of metal with surface treatment. Rotor supported

on  bearings  providing  a  low  noise  level,  speed  adjustment  in  clockwise  and  counterclockwise 

directions, adapts to any contra angle or straight piece handpiece in the INTRA system.

The Alliage handpieces have been planned to offer maximum performance in the most severe clinical

procedures. With a design which caters for ergonomics, torque, sensitivity and lightness. Produced

with technology (MADE IN BRAZIL) and material of the utmost durability.

Internal irrigation System (according to model acquired): without the need for adaptations, the 

internal irrigation system allows direct passage of water flow to the counter angle or straight piece

with the power required for the formation of the spray.

To ensure safe operation of your equipment, use only the mounting assembly (chair, equip, water

unit and reflector) provided by Alliage Authorized Reseller Service.

Application specification

Alliage Dental Handpieces are designed to perform most routine dental procedures in intraoral 

region treatments.

Operation principle

The Air motors operates by pneumatic pressure and has an Intra connection system to be used 

with Low Speed Dental Handpieces.

Significant physical characteristics

The Air motors promotes shaft revolutions in the magnitude of 5,000 to 20,000 revolutions/minute 

and has a torque of 0.350 - 1,000 N.cm. Under normal operating conditions, the equipment has a 

compressed air consumption of 54 L/min and a water consumption of 42 mL/min.

User profile

Alliage Dental Handpieces can be operated and handled by users of both sexes, with the ability to

read and understand images, symbols, icons, western Arabic characters (Arial font), alpha numeric

characters, knowing how to distinguish intraoral part of the human body, not being able to present

a degree of visual imperfection for reading or seeing and an average degree of impairment of recent

memory, not being in a clear capacity to perform the activities and functions of the product in a 

correct manner to the profession.

The user needs to be a qualified health professional and trained with technical competence in the

health and dentistry field.

Содержание MICROMOTOR INTRA SL 30 TB SI

Страница 1: ......

Страница 2: ...ROMOTOR INTRA SL 30 TM SI Brand Dabi Atlante Manufacturer Distribuitor Alliage S A Indústrias Médico Odontológica C N P J 55 979 736 0001 45 Insc Est 582 002 897 114 Rod Abrão Assed Km 53 450m Cx Postal 782 CEP 14097 500 Ribeirão Preto S P Brasil Telefone 55 16 3512 1212 Technical Duties Daniel R de Camargo CREA SP 5062199650 Registro ANVISA nº 10069210073 For greater safety Read and understand al...

Страница 3: ...ronmental conditions in regular use conditions 12 Precautions and warnings during the use of equipment 13 Precautions and warnings after the use of equipment 13 Precautions in case of alteration in the functioning of equipment 13 Precautions to be adopted against foreseeable or uncommon risks related to the deactivation and abandoning of equipment 13 Environmental impact reduction precautions 14 E...

Страница 4: ...problems Please read it and keep this with you Indication of Use The Alliage handpieces are intended to remove caries remove restorations and perform tooth sectioning as an aid in extracting teeth and they are for exclusive dental use and must be handled by trained qualified and regulated health professionals according to local legislation Contraindication None known ...

Страница 5: ...n Alliage Dental Handpieces are designed to perform most routine dental procedures in intraoral region treatments Operation principle The Air motors operates by pneumatic pressure and has an Intra connection system to be used with Low Speed Dental Handpieces Significant physical characteristics The Air motors promotes shaft revolutions in the magnitude of 5 000 to 20 000 revolutions minute and has...

Страница 6: ...e of an informative nature the equipment being able to differ from that illustrated So upon acquiring the product check the technical compatibilty between equipment coupling and accessories Models 01 Micromotor Intra SL 30 C Spray TB TM 02 Micromotor Intra SL 30 S Spray TB Micromotor Intra 32 MM S Spray TB 03 Micromotor Intra 32 MM C Spray TB TM Micromotor Intra SL 30 TB SI Micromotor Intra SL 30 ...

Страница 7: ...g TB TM 02 O ring 03 Lubricant Lubs Attention The use of any part accessory or material not specified or foreseen in these instructions for use is entirely the user s responsibility Sets and Parts DESCRIPTION OF EQUIPMENT Optional ...

Страница 8: ...pe 04 holes Coupling via the INTRA system Straight Piece and Contra Angle Sterilization Autoclavable up to 135ºC Coupling type Type 2 According to ISO 3964 Length X1 Long type max 31 8mm According to ISO 3964 Torque 0 350 1 000 N cm TECHNICAL SPECIFICATIONS General features Weights Model Net Weight Gross Weight 32 MM 77g 137g SL 30 80g 140g ABBREVIATIONS MM Air motors S Spray C Spray With Spray S ...

Страница 9: ...e taken to a special waste collection site at the end of its useful life Attention Manufacturer Serial number Model number Manufacturing date To indicate a reference to spraying liquid Instructions for use Borden Type Terminal Stacking limit by number Keep dry This side Up Keep out of sunlight Fragile handle with care Temperature limitation 10 TECHNICAL SPECIFICATIONS ...

Страница 10: ...10 Midwest Type Terminal Variability to the right Variability to the left Dimensions mm TECHNICAL SPECIFICATIONS BORDEN TYPE WITH SPRAY MIDWEST TYPE WITH SPRAY ...

Страница 11: ...e wear of the bearings For the handpiece to function well it is necessary to have a driving pressure of 275 79 kpa 40 psi 2 75 bar Ring lock unlock Ring lock unlock fig a fig d fig c Regulator Ring fig b Type BORDEN Type MIDWEST Coupling of Air motors with handpieces Straight handpiece and Contra Angle Attaching the Contra Angle or Straight Part in the coupling of Air motors fig c To disengage by ...

Страница 12: ...dictable environmental conditions in regular use conditions The equipment has been planned not to be sensitive to interference such as magnetic fields external electrical factors electrostatic discharge pressure or variance of pressure provided that the equipment is installed maintained clean preserved transported and operated as per this instruction for use Precautions and warnings during the use...

Страница 13: ...ch it is intended Damages caused to the equipment the professional and or the patient by the incorrect installation and erroneous procedures of maintenance differing from those described in these Instructions for use which come with the equipment or by the incorrect operation of it Precautions for the Reduction of the Environment Impact Alliage S A aims to achieve an environmental policy that enco...

Страница 14: ...d spread it on the surface to be treated Respect the antimicrobial contact time specified by the manufacturer The equipment can be reused in undetermined i e unlimited quantities only needing to be cleaned disinfected and Sterilization Additional procedures for reuse Handpieces may only be serviced in the field at the points described in the user manual If they need to be disassembled they must be...

Страница 15: ...t the lubrication of your equipment we recommend the use of the Lubs product Lubrication must be carried out by the posterior hole of Air motors as illustrated in fig a Firmly fit the oil applicator nozzle into the hole indicated in fig a and apply the spray for 1 or 2 seconds fig b by holding the vial in vertical position Perform these operations spray lubrication with the regulating ring positio...

Страница 16: ...e Attendance Service Alliage 55 16 3512 1212 Item Inspection description Recommended frequency Operating noise Audibly check the equipment for any ab normalities Daily Coupling Make sure that the Air motors is well fixed to the Delivery Unit terminal Daily Water leak Check if the spray holes are leaking water Monthly Clogging Check that the spray holes are not blocked Monthly Periodic Inspection I...

Страница 17: ...screwdriver push the lining carefully downwards fig c Spray Regulation Spray cooling requires at least 50 cm3 min of water An insufficient amount of water can lead to overheating of the tooth With the terminal register open and the instrument working with Bur slowly close the register until the desired spray is achieved Maintenance of the MIDWEST Type Lining Use the same procedure as the BORDEN ty...

Страница 18: ...ance of O Ring Change Insert a screwdriver of 1 2mm in the channel of the O ring moving it outwards fig a and b In order to fasten the new ring execute the opposite process without the screwdriver fig c INSPECTION AND MAINTENANCE ...

Страница 19: ... spare parts replacement To ensure the lifetime of your device only replace original spare parts from Alliage They have the assurance of the standards and technical specifications required by the Alliage representative We call your attention to our authorized resellers chain Only this chain will keep your equipment constantly new because it has trained technical assistant and specific tools for th...

Страница 20: ......

Отзывы: