SS6 – SS7 – SS8 – SS10 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

Содержание SS6

Страница 1: ...NDERHOUD INSTRUCCIONES PARA LA INSTALACION Y EL MANTENIMIENTO INSTALLATIONS OCH UNDERHÅLLSANVISNING Ο ΗΓΙΕΣ ΓΙΑ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΚΑΙ ΤΗ ΣΥΝΤΗΡΗΣΗ KULLANIM VE BAKIM TALİMATLARI ИНСТРУКЦИИ ПО МОНТАЖУ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ INSTRUCŢUNI PENTRU INSTALARE ŞI ÎNTREŢINERE INSTRUÇÕES PARA A INSTALAÇÃO E A MANUTENÇÃO INSTRUKCJE OBSŁUGI I KONSERWACJI INSTALLÁCIÓS ÉS KARBANTARTÁSI UTASÍTÁS ا دات إر وا SS6...

Страница 2: ...AIS page 9 ENGLISH page 17 DEUTSCH seite 24 NEDERLANDS bladz 32 ESPAÑOL pág 40 SVENSKA sid 48 ΕΛΛΗΝΙΚΑ σελ 56 TÜRKÇE sayfa 64 РУССКИЙ cтр 72 LIMBA ROMÂNĂ pag 80 PORTUGUÊS pág 88 POLSKI str 96 MAGYAR oldal 104 112 ªRte IZk ...

Страница 3: ...hat they do not play with the appliance Ensure that the product has not suffered any damage during transport or storage Check that the outer casing is unbroken and in excellent conditions 1 1Safety Use is allowed only if the electric system is in possession of safety precautions in accordance with the regulations in force in the country where the product is installed for Italy CEI 64 2 1 2 Respons...

Страница 4: ...antifreeze mixture to prevent internal freezing up to 30 C Motors should not be stored or installed with lower temperatures or for periods longer than 12 months however if this is unavoidable turn the shaft by hand once a month If the motor has been stored for more than 12 months disassemble it and check rotating parts and thrust bearing Just before installation drain completely the motor from the...

Страница 5: ...brackets placed alternately on the pump column pipe Proceed in the following way a Connect the first column section to the pump delivery nozzle after having placed a splitted supporting bracket at the opposite end of the pipe In case of threaded column pipes place by the upper end the suited threaded sleeve to avoid possible sliding between pipe and bracket b Move the assembly with a hoist and low...

Страница 6: ...no cuts cracks scratches or other damages If two cables have to be joined in parallel pay extreme attention when connecting cables of the same color 6 2 Electric system The motor is connected by the supply cable to the control panel which contains the necessary control and protection devices Since every difficulty either mechanical or electric will damage almost automatically the motor windings it...

Страница 7: ...ages when lowering the pump in the well If the results are negative lift the group again and check it thoroughly For three phases units the electric resistance value should be nearly the same for each phase Check insulation resistance to the ground i e between cable end and discharge pipe using a megahoms meter Minimum value to the ground for a new pump is 10 megahoms with cold motor However if so...

Страница 8: ...onstruction features the pump and motor group easily disassembled and re assembled with normal metric size shop tools If the pump adopts a non return valve consider the additional weight of the water filled column besides the group weight and use therefore a suited hoist We suggest to employ specialized personnel for assembling and disassembling 9 2 Assembling the pump motor group Check the free r...

Страница 9: ...he pump is running A Too low voltage B Overload due to sand clogging bearings tend to saize C Single phase a voltage 1 5 2 times higher than normal runs through motor windings so the starter trips stopping the unit D The starter is installed in a too warm place E The starter in not correctly calibrated F Electropump blocked in a crooked sinkhole with consequent abnormal value of the absorbed curre...