background image

5

GB

submersed for it to operate correctly, but can be used at a minimum suction height of 50 mm for very short 
periods.  

Characteristics: 

¾

 

Optimum motor cooling that allows the pump to be used also when it is only partially submersed. 

¾

 

Stainless steel anti-deposit filter 

¾

 

Non-return valve and 4-way connector.

 

 

Equipped with: 

¾

 

anti-oxidation and anti-corrosion materials  

¾

 

AISI 316 stainless steel motor casing, drive shaft and bolts. 

 The temperature of the fluid being pumped must never exceed 35° C

 The pump must not be used to pump salt water (unless specifically designed for the purpose), 
sewage  (except  for  submersible  pumps  suitable  for  pumping  dirty  water  with  solid  particles 
having  a  maximum  diameter  of  38  mm),  flammable,  corrosive  or  explosive  liquids  (e.g. 
petroleum oil, petrol, thinners), grease, oils or foodstuffs. 

 Comply with the rules and regulations of the local water authority when using the pump for the 

          supply of domestic water. 

 
3.   STARTING THE PUMP 

 Before starting the pump, make sure that:

 

x

 

the voltage and frequency specified on the pump’s nameplate coincide with those of the available power 
supply; 

x

 

there are no signs of damage to the pump or its power cord; 

x

 

the electric connection is made in a dry place, protected against any risk of flooding; 

x

 

the  electric  system  is  complete  with  a  residual  current  circuit-breaker  (I 

¨

”

  30  mA)  and  an  efficient 

earthing connection; 

x

 

Any extension cords must comply with the requirements of the DIN VDE standard 0620. 

 

Note

:  given  the  different  provisions  applicable  to  the  safety  of  electric  systems  in  different  countries, 

make sure that the pump system, as concerns its intended use, is in accordance with current legislation. 

 
Insert the plug of the power cable into a suitable power socket.  

Automatic operation: 

The floating switch starts and stops the pump automatically.  
The water level that prompts the starting and stopping of the pump can be adjusted by changing the length of 
cable of the float between the holder and the float.  
N.B. The length of the float cable must never be shorter than 10 cm. 

Manual operation: 

a) 

The floating switch must be lifted in order to start pumps with a float. 

b) 

For pumps without a float, insert the plug. 

 
4. RECOMMENDATIONS 

To ensure the proper operation of the pump, it is important to comply with the following recommendations: 

x

 

The pump must never be allowed to run dry. 

x

 

Never leave the pump in operation when the delivery pipe is clogged. 

x

 

The  pump  must  only  be  used  when  it  is  immersed  in  water.  If  the  water  runs  out,  the  pump  must  be 
stopped immediately by removing the plug from the power supply. 

x

 

Pay careful attention when the pump is operated in manual mode. 

x

 

The pump must be placed in a stable position inside a trap or in the lowest part of the place where it is 
installed. 

x

 

The float must be able to move freely while the pump is running therefore the advised dimensions of the 
trap are 40x40 cm.  

Available in an automatic version with fl oat switch for automatic starting and stopping of the pump. 

Multipurpose submersible pumps designed specifi cally for use in salt water. (NOVA SALT W). 

Содержание NOVAPOND

Страница 1: ...MANUAL MANUEL D INSTRUCTIONS MANUALE D ISTRUZIONI BETRIEBSANLEITUNG MANUAL DE INSTRUCCIONES INSTRUCTIEHANDLEIDING OHJEKIRJA MANUAL DE INSTRUÇÕES BRUKSANVISNING РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ý ý NÁVOD NA OBSLUHU ý ý ПРИРАЧНИК СО ИНСТРУКЦИИ NOVAPOND DIVER 6 NOVA SALT W ...

Страница 2: ...04 108 CE Electromagnetic Compatibility Directive en conform de volgende normen EN 60335 1 08 Household and Similar Electrical Appliances Safety EN 60335 2 41 05 Particular Requirements for Pumps FI EY VAATIMUSTENMUKAISUUSVAKUUTUS Me DAB Pumps S p A Via M Polo 14 Mestrino PD Italy vakuutamme ottaen täyden vastuun että tuotteet joita tämä vakuutus koskee ovat seuraavien direktiivien 2006 95 CE Low ...

Страница 3: ...N 60335 2 41 05 Particular Requirements for Pumps RS ME IZJAVA O PODUDARANJU CE Mi DAB Pumps S p A Via M Polo 14 Mestrino PD Italy izjavljamo na našu potpunu odgovornost da proizvodi na koje se ova izjava poziva podudaraju se sa sljedeþim pravilima 2006 95 CE Low Voltage Directive 2004 108 CE Electromagnetic Compatibility Directive kao što i sa sljedeþim propisima EN 60335 1 08 Household and Simil...

Страница 4: ...ump read this instruction booklet carefully For safety reasons the pump must not be used by anyone who has not read these instructions The appliance is not intendend for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction con cerning use of the appliance by a person respons...

Страница 5: ...e DIN VDE standard 0620 Note given the different provisions applicable to the safety of electric systems in different countries make sure that the pump system as concerns its intended use is in accordance with current legislation Insert the plug of the power cable into a suitable power socket Automatic operation The floating switch starts and stops the pump automatically The water level that promp...

Страница 6: ...e pump is not enabled by the float B Make sure the float can move freely Increase the depth of the pit The pump delivers no water A The suction grid or piping are clogged B The impeller is worn or stuck C The required head is too high for the characteristics of the pump D Water level under the suction minimum A Remove the obstruction B Replace the impeller or remove the obstruction The pump does n...

Страница 7: ...used correctly and in compliance with the instructions The guarantee becomes null and void in the event of the following y unauthorized attempts to repair the appliance y unauthorized technical changes to the appliance y use of non original spare parts y manhandling y inappropriate use e g for industrial purposes The guarantee does not cover y parts liable to rapid wear and tear For any action und...

Отзывы: