1 Introduction
This booklet contains instructions for the use and maintenance of the Idea series water pumps, both single phase and three phase. The
Idea electropump has been designed to pump clean water not containing abrasive particles it can be used in wells with a minimum
diameter of 100 mm (4"), as well as in containers or cisterns. The use of the pump for irrigation, gardening, and in the residential and
household field is subject to local legislation. Before installing and using the pump, read the following instructions carefully.
Read this manual carefully bifore installing and using the product.
The manufacturer declines any responsibility in case of accidents or damages caused by improper use of the water pump or due to
negligence or lack of observance of the instructions described in this booklet or use of the pump under conditions that differ from the
ratings on the nameplate.
2 Description of water pump
The electopump Idea is supplied in a solid carton box, with its instruction booklet, ready for installation, complete with electric cable.
These are Idea data :
1 phase pumps Idea(2 WIRES)
Power
MAX
I
MAX
Capacitor
Fatt. Pot. Capacity L/min Head m.c.a.
Model W Amp.
mF Cos.Fi
min
max
min
max
75M
800 4 16 0,89
7
42
4
39
100M
1100 4,7 20
0,89 7
42
5
52
3 phase pumps Idea
Power
MAX
I
MAX
Fatt. Pot. Capacity L/min Head m.c.a.
Model W Amp.
Cos.Fi
min
max
min
max
75T
650 1,5
0,78 7
42
4
39
100T
1100 2,3 0,78 7
42
5
52
3 Stocking and handling
The pump should be stocked in vertical position, in a clean and dry place and inside its original packing. When storing do not put
weights or other boxes on top.
Never lift or transport the pump by its electric cable.
4 Preliminary inspection
Unpack the pump and check its integrity in all its components.
Check that the data on the nameplate are according to your needs. In particular the electrical data (voltage, phase number,
frequency, rated power and amps) have to correspond with those of the power supply where you want to connect the pump.
Check, in the case of a preinstalled control box and of a single phase pump that the value of the capacitor is according to the one
stamped on the nameplate.
In case of anomalies or any doubt please immediately contact your supplier or service point signaling the facts.
Never use the pump in case of doubts about its safety or its use.
5 Conditions of use
The following conditions must be observed when using the water pump:
Temperature of pumping liquid between : Min. +0°C – Max. +35°C
Max. depth : 20 mt
Voltage variation allowed : +6%/-10%
Starti for hour : Max. 20