11. FACTORY SETTINGS
Parameter
Value
Regulating mode
= Proportional differential pressure
regulation
Twin operating mode
= Alternate every 24h
Pump start control
ON
12. TYPES OF ALARM
Alarm Code
Alarm Symbol
Alarm Description
e0 - e16; e21
Internal Error
e17 - e19
Short Circuit
e20
Voltage Error
e22 - e31
Internal Error
e32 - e35
Electronic system excess temperature
e37
Low voltage
e38
High voltage
e39 - e40
Pump blocked
e46
Pump Disconnected
e42
Dry operation
e56
Motor excess temperature (motor
protector trips)
e57
Frequency of PWM external signal less
than 100 Hz
e58
Frequency of PWM external signal
greater than 5 kHz
Table 1: Factory settings
Table 2: List of alarms
INFORMATION
Frequently asked questions (faq) on the ecodesign directive 2009/125/ec establishing a
framework for the setting of ecodesign requirements for energy-related products and its
implementing regulations:
http://ec.europa.eu/enterprise/policies/sustainable-business/documents/eco-de
-
sign/guidance/files/20110429_faq_en.pdf
Guidelines accompanying commission regulations implementing the ecodesign directive:
http://ec.europa.eu/energy/efficiency/ecodesign/legislation_en.htm - see “circula
-
tors.
13. ERROR CONDITION AND RESET
Display
indication
Description
Reset
e0 – e16
Internal error
-Switch off system power.
-Wait for the warning lights on the control
panel to go off, then power the system
again.
-
If the error persists, change the circu
-
lator.
e37
Low mains
voltage (LP)
-Switch off system power.
-Wait for the warning lights on the control
panel to go off, then power the system
again.
-
Check that the mains voltage is correct,
if necessary reset it at the plate values.
e38
High mains
voltage (HP)
-Switch off system power.
-Wait for the warning lights on the control
panel to go off, then power the system
again.
-
Check that the mains voltage is correct,
if necessary reset it at the plate values.
e32-e35
Critical over-
heating of
electronic parts
-Switch off system power.
-Wait for the warning lights on the control
panel to go off.
-Check that the system ventilation ducts
are not blocked and that the environ-
ment temperature of the premises is
correct.