ENGLISH
95
6.
KEY TO INDIVIDUAL PARAMETERS
6.1
User menu
The USER MENU is accessed by pressing MODE (or via the selection menu by pr or - ). Within this menu, again by
pressing MODE, the following values are displayed consecutively.
6.1.1
FR: Display of rotation frequency
Current rotation frequency with electric pump is controlled, in [Hz].
6.1.2
VP: Display of pressure
System pressure measured in [bar] or [psi] depending on measurement system used.
6.1.3
C1: Display of phase current
Phase current of electric pump in [A]
A round flashing symbol may appear under the phase current C1symbol. This signals that the pre-alarm threshold of maximum
current allowed has been exceeded. If the symbol flashes at regular intervals it means that the motor overcurrent protection is being
activated and that it will probably be triggered. In this case it is necessary to check the correct setting of the maximum current of the
RC pump, see paragraph 6.5.1 and the electric pump connections.
6.1.4
PO: Display of the power delivered
Power delivered to the electric pump in [kW].
A round flashing symbol may appear under the measured power PO symbol. This signals that the pre-alarm threshold of maximum
power allowed has been exceeded.
6.1.5
SM: System monitor
Displays the system status in the case of a multi-inverter installation. If there is no communication, an icon is displayed, showing
communication absent or interrupted. If there are several interconnected inverters, an icon is shown for each. The icon bears the
symbol of a pump with pump status indications below.
Depending on operating status, the item in Table 15 is displayed.
System display
Status
Icon
Status information below icon
Inverter in run
Symbol of pump running
Frequency implemented on 3 digits
Inverter in standby
Symbol of static pump
SB
Inverter in fault
Symbol of static pump
F
Table 15: Display of SM system monitor
If the inverter is configured as reserve, the upper section of the icon representing the motor is displayed in colour, while the display
remains the same as in Table 15 with the exception that if the motor is stationary F is displayed instead of Sb.
If one or more inverters have RC without a setting, the letter A appears in place of the status information (below all icons of the
inverters present), and system start-up is disabled.
To reserve more space for the system display, the name of the parameter SM is not shown, but simply the text
“system” below the menu name
.
Содержание PWM 203
Страница 13: ...ITALIANO 11 Figura 2 Fissaggio e distanza minima per la circolazione d aria...
Страница 73: ...ENGLISH 71 Figure 2 Fixture and minimum clearance for air circulation...
Страница 129: ...FRAN AIS 127 Figure 2 Fixation et distance minimum pour la circulation de l air...
Страница 185: ...DEUTSCH 183 Abbildung 2 Befestigung und Mindestabstand f r die Luftzirkulation...
Страница 244: ...ESPA OL 242 Figura 2 Fijaci n y distancia m nima para la circulaci n del aire...
Страница 295: ...293 IEC 60634...
Страница 296: ...294 1 6 1 1...
Страница 300: ...298 1 2 5 2 1 2 1 2 2...
Страница 301: ...299 2...
Страница 302: ...300 2 2 3 3 15 2 2 1 4 2 2 1 1 PWM 203 202 201 3 1 LN 4 2 3...
Страница 306: ...304 6 2 2 3 3 Press e Flow 7 A B C D...
Страница 308: ...306 8 4 20 5 4 20 PR 6 5 7 4 20 2 18 J5 GND 1 J5 GND o IN 11 J5 o OUT 7 J5 4 20 7 OUT 8 10 11 IN...
Страница 311: ...309 DC AC 50 60 8 6 2 1 5 36 36 12 3 3 3 3 2 13 7 11 8 11...
Страница 313: ...311 9 MODE 1 SET 9 3 EEprom SET 6 SET MODE 3 1 11 3 2 1 2 3 2 1 MODE SET MODE 10...
Страница 315: ...313 SO AE MP I1 1 I2 2 I3 3 I4 4 O1 1 O2 2 RF PW 11 3 2 2 13 SET 13 15 14...
Страница 316: ...314 14 3 3 12 GO SB BL LP HP EC OC OF SC OT...
Страница 317: ...315 12 15 13 15 3 4 PW 6 6 16 OB BP NC F1 F3 F4 P1 1 P2 2 P3 3 P4 4 E0 E16 0 16 EE EEprom WARN GO SB...
Страница 318: ...316 4 4 1 Link 8 4 2 4 2 1 Link Link 16...
Страница 319: ...317 16 Link 4 2 2 0 5V 4 20 A 0 4 2 2 1 FI FI 4 2 2 2 FZ 6 5 9 1 4 2 2 3 0 5 4 20 A 0 5 0 5 4 20 A 2 2 3 1...
Страница 322: ...320 4 4 2 2 4 2 5 4 5 ET 6 6 9 FL 4 5 1 4 5 1 1 ET ET ET ET 0 ET 6 6 9 4 5 1 2 23 23...
Страница 327: ...325 15 SB F 15 SM 15 F Sb RC A SM 6 1 6 VE 6 2 2 SET MODE 6 2 1 VF 6 2 2 TE 6 2 3 BT 6 2 4 FF FF x y x y x 1 x y 64 RF...
Страница 344: ...342 FF 6 6 16 PW PW 0 PW 0 PW XXXX 10 PW 2 10 0 Mode Set PW 0 PW 2 7 3 6 6 16 1 PW PW PW PW 0 PW 0 0 PW PW PW PW PW 0 PW...
Страница 359: ...NEDERLANDS 357 Afbeelding 2 Bevestiging en minimumafstand voor luchtrecirculatie...
Страница 418: ...SVENSKA 416 Fig 2 Fasts ttning och min utrymme f r luftcirkulation...
Страница 473: ...T RK E 471 ekil 2 Hava sirk lasyonu tesisat ve minimum a kl k...
Страница 523: ...520 IEC 364 inverter...
Страница 524: ...521 1 Inverter inverter inverter 6 inverter 1 1...
Страница 528: ...525 1 2 1 1 inverter inverter 1 1 2 5 inverter 2 1 inverter 2 1 2 2 C...
Страница 529: ...526 2...
Страница 530: ...527 2 2 3 3 inverter 15 inverter 2 2 1 inverter inverter 4 2 2 1 1 PWM 203 202 201 inverter 3 1 LN 4 inverter 2...
Страница 534: ...531 6 2 2 3 3 Press Flow 7 A B C D...
Страница 539: ...536 DC V AC 50 60 Hz Vrms V 8 6 V 2 1 5 V 36 36 12V mA 3 3 3 3 mm 2 13 7 11 8...
Страница 540: ...537 11 J5 pin Pin I1 11 17 16 18 16 17 I2 11 15 16 18 15 16 I3 11 14 13 18 13 14 I4 11 12 13 8 12 13 8...
Страница 542: ...539 9 3 EEprom SET 6 SET MODE 3 1 11 3 2 1 2 3 2 1 MODE SET Setpoint MODE 10 ONOMA TOY MENOY 2 Setpoint 2 5 5 5...
Страница 545: ...542 14 3 3 go Hz bar psi 12 GO SB BL LP HP EC OC OF SC OT...
Страница 588: ...ROM N 585 Figura 2 Fixarea i distan a minim pentru circula ia aerului...
Страница 635: ...01 20 cod 60198807...