7.3. 

 

Site of installation of the PULSAR DRY 

• 

A solid anchoring of the pump to its support base helps absorb any vibrations created by 
pump operation.

 

• 

Block the pipes with their own supports and connect them so that they do not exert strain, 
stress or vibration on the pump inlets.

 

• 

It is always good practice to position the pump as close as possible to the liquid to be 
pumped.

 

• 

It is recommended to fit a foot valve on intake. To avoid the formation of air pockets in the 
suction pipe, ensure that the suction pipe is tilted slightly towards the electropump. 

• 

Provide a hole for priming the pump in the delivery pipe (see paragraph. 9.1). 

 

7.4. 

 

Working conditions of the PULSAR DRY 

• 

Water temperature: from 0°C to + 40°C. 

• 

The electropump cannot operate when dry. 

• 

Install in vertical position. 

• 

If installed in a pit, the pit must be free from frost. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

vent

pipe

supports

non return

valve

filling

cap

drainage
cap

pipe
supports

system

drainage

foot

valve

filter

installation
on intake

installation

below

head

        non return

valve

filter

Fig. 2

 

PULSAR DRY 

Содержание PULSAR DRY 30/50

Страница 1: ...erordnung ber die elektromagnetische Kompatibilit t 89 336 und folgende Ab nderungen Verordnung ber Schwachstrom 73 23 und folgende Ab nderungen CONFORMITEITSVERKLARING De firma DAB PUMPS s p a Via M...

Страница 2: ...in conformitate cu Directiva Consiliului nr 98 37 CE privind armonizarea legislatiilor Statelor membre CEE referitoare la masini cu modificarile sale ulterioare Directiva referitoare la compatibilita...

Страница 3: ...and damage to the equipment but invalidates every right to assistance under guarantee Keep this manual with care for further consultation even after the first installation 2 APPLICATIONS PULSAR electr...

Страница 4: ...AR DRY 65 50 65 506 10 4 PULSAR DRY 20 80 PULSAR PULSAR DRY 30 80 30 806 8 4 PULSAR PULSAR DRY 40 80 40 806 8 4 PULSAR PULSAR DRY 50 80 50 806 10 4 Liquid temperature range from 0 C to 40 C Maximum im...

Страница 5: ...in a horizontal position Remover the filter cover slackening the three screws with a screwdriver Using a size 13 box spanner slacken the self locking nut and turn the motor shaft in a clockwise direct...

Страница 6: ...m after installation will not be sucked up Remove the sediment periodically It is very important to ensure that the water level never falls below the body of the pump Fig 1 7 2 Working conditions of t...

Страница 7: ...alve on intake To avoid the formation of air pockets in the suction pipe ensure that the suction pipe is tilted slightly towards the electropump Provide a hole for priming the pump in the delivery pip...

Страница 8: ...its the maximum depth of immersion at which the pump may be used Dry operation of the pump causes irreparable damage to the mechanical seal 8 ELECTRICAL CONNECTION CAUTION ALWAYS FOLLOW THE SAFETY REG...

Страница 9: ...rt two phases on the supply line 3 Restart the pump and check the water flow rate again 4 Stop the pump The correct direction of rotation is the one that gives the higher flow rate 9 STARTING 9 1 9 2...

Страница 10: ...the pump at normal temperature If the pump has been used with substances that tend to deposit rinse it after use with a powerful jet of water so as to avoid the formation of deposits or scale which w...

Страница 11: ...f the float switch cable See chapter on Warnings Paragraph 9 3 F Prime the pump See Fig 2 3 The pump does not stop A The float does not interrupt pump operation A Check that the float moves freely and...

Отзывы: