DAB PUMPS PULSAR DRY 30/50 Скачать руководство пользователя страница 5

ENGLISH 

21 

6.   WARNINGS 

6.1.  

Skilled technical personnel 

 

It is advisable that installation be carried out by skilled personnel in 
possession of the technical qualifications required by the specific 
legislation in force

.

 

The term 

skilled personnel

 means persons whose training, experience and instruction, as well 

as their knowledge of the respective standards and requirements for accident prevention and 
working conditions, have been approved by the person in charge of plant safety, authorizing 
them to perform all the necessary activities, during which they are able to recognize and avoid 
all dangers. (Definition for technical personnel IEC 364).

 

6.2.  

Safety 

-  Use is allowed only if the electric system is in possession of safety precautions in accordance with the 

regulations in force in the country where the product is installed (for Italy, CEI 64/2). 

- The 

pump 

must 

never

 be allowed to run dry. 

-  The pump cannot be used in swimming pools, ponds or tanks in which people are present. 
-  The pump is provided with a hook to which a rope or cable may be connected to lower the machine into 

working position. 

The pumps must never be carried, lifted or made to operate hanging from their 

power cables.

 

-  Qualified personnel must be employed for all electrical repairs which, if badly carried out, could cause 

damage and accidents. 

6.3.  

Checking rotation of the PULSAR motor shaft. 

If the motor does not work and the shaft does not turn when the switch and/or float is operated, you must 
check that the moving parts are turning freely. 
To do this: 
-  Completely disconnect the pump from the power mains. 
-  Place the pump in a horizontal position. 
-  Remover the filter cover, slackening the three screws with a screwdriver. 
-  Using a size 13 box spanner, slacken the self-locking nut and turn the motor shaft in a clockwise 

direction. 

-  Replace the filter cover and install the pump as indicated in chapter 7. 

6.4.  

Checking rotation of the PULSAR DRY motor shaft. 

If the motor does not work and the shaft does not turn when you switch on the pump, you must check that the 
moving parts are turning freely. 
To do this: 
-  Completely disconnect the electropump from the electric power mains. 
-  Place the electropump in horizontal position. 
-  Remove the steel base, slackening the eight screws and nuts with a spanner. 
-  Using a size 13 hexagonal box spanner, adjust the self-locking nut and turn the motor shaft in a 

clockwise direction. 

-  Replace the steel base and install the electropump as indicated in chapter 7. 

6.5.  

Cleaning the PULSAR filter. 

To clean the filter, proceed as follows: 
-  Place the pump in a horizontal position. 
-  Remover the filter cover, slackening the three screws with a screwdriver. 
-  Clean the inside of the filter, removing any particles that may have been sucked in. 
-  Check that the various filter slots are free from foreign bodies. 
-  Replace the filter cover and install the pump as indicated in chapter 7. 

 
 

6.6.  

Responsibility 

 
 

 

The Manufacturer does not vouch for correct operation of the pumps if they are 
tampered with or modified, run outside the recommended work range or in contrast with 
the other instructions given in this manual. 

 

The Manufacturer declines all responsibility for possible errors in this instructions 
manual, if due to misprints or errors in copying.  The company reserves the right to make 
any modifications to products that it may consider necessary or useful, without affecting 
the essential characteristics.

 

 

Содержание PULSAR DRY 30/50

Страница 1: ...erordnung ber die elektromagnetische Kompatibilit t 89 336 und folgende Ab nderungen Verordnung ber Schwachstrom 73 23 und folgende Ab nderungen CONFORMITEITSVERKLARING De firma DAB PUMPS s p a Via M...

Страница 2: ...in conformitate cu Directiva Consiliului nr 98 37 CE privind armonizarea legislatiilor Statelor membre CEE referitoare la masini cu modificarile sale ulterioare Directiva referitoare la compatibilita...

Страница 3: ...and damage to the equipment but invalidates every right to assistance under guarantee Keep this manual with care for further consultation even after the first installation 2 APPLICATIONS PULSAR electr...

Страница 4: ...AR DRY 65 50 65 506 10 4 PULSAR DRY 20 80 PULSAR PULSAR DRY 30 80 30 806 8 4 PULSAR PULSAR DRY 40 80 40 806 8 4 PULSAR PULSAR DRY 50 80 50 806 10 4 Liquid temperature range from 0 C to 40 C Maximum im...

Страница 5: ...in a horizontal position Remover the filter cover slackening the three screws with a screwdriver Using a size 13 box spanner slacken the self locking nut and turn the motor shaft in a clockwise direct...

Страница 6: ...m after installation will not be sucked up Remove the sediment periodically It is very important to ensure that the water level never falls below the body of the pump Fig 1 7 2 Working conditions of t...

Страница 7: ...alve on intake To avoid the formation of air pockets in the suction pipe ensure that the suction pipe is tilted slightly towards the electropump Provide a hole for priming the pump in the delivery pip...

Страница 8: ...its the maximum depth of immersion at which the pump may be used Dry operation of the pump causes irreparable damage to the mechanical seal 8 ELECTRICAL CONNECTION CAUTION ALWAYS FOLLOW THE SAFETY REG...

Страница 9: ...rt two phases on the supply line 3 Restart the pump and check the water flow rate again 4 Stop the pump The correct direction of rotation is the one that gives the higher flow rate 9 STARTING 9 1 9 2...

Страница 10: ...the pump at normal temperature If the pump has been used with substances that tend to deposit rinse it after use with a powerful jet of water so as to avoid the formation of deposits or scale which w...

Страница 11: ...f the float switch cable See chapter on Warnings Paragraph 9 3 F Prime the pump See Fig 2 3 The pump does not stop A The float does not interrupt pump operation A Check that the float moves freely and...

Отзывы: