DAB PUMPS LEADER ECOTRONIC Series Скачать руководство пользователя страница 8

 

 

5. 

 

TROUBLESHOOTING

 

 

 

Before taking any troubleshooting action, disconnect the pump from the power supply. 
lf there is any damage to the power cord or pump, any necessary repairs or replacements must 
be handled by the manufacturer or his authorized customer support service. or by an equally- 
qualified party, In order to prevent all risks. 

 

 

Multi-impeller self priming Surface pump and boosters with tanks 

 

FAULT

 

CAUSE

 

SOLUTION

 

1.

 

The  pump  does  not 
turn on 

1)No power 
 
2) Shaft blocked 

1) Check if power is supplied to the socket and that 
the plug is correctly inserted 
2)  Remove  the  plug  from  the  power  socket  and 
insert  a  screwdriver  into  the  notch  on  the  shaft 
(from  the  cooling  fan  side)  and  unblock  it  by 
turning the screwdriver 

 

 

 

2.

 

The pump turns but 
does not deliver 
water 

1)  The  air  inside  the  pump  has  not 
been  completely  bled.  Pump  casing 
without water 

 
 

2) Entry of air from the suction pipe. 
 
 
 
 
3) The suction valve is not submerged 
in the water 
-suction valve blocked 
-the  maximum  suction  depth  has  been 
exceeded. 

1) stop the pump, unscrew the delivery pipe, shake 
the  pump  and  suction  hose  to  remove  any  air 
bubbles.  Top  up  with  water,  connect  the  hose  and 
delivery  pipe  ensuring  it  is  correctly  sealed  and 
start the pump again. 
2)  check  that  the  joints  of  the  suction  hose  have 
been  performend  correctly.  Make  sure  that  there 
are  no  counterslopes,  traps,  goosenecks  or 
constrictions  on  the  suction  pipe  and  that  the 
suction valve is not blocked. 
3) place the suction valve in the water 
- clean the foot valve 
- clean the suction basket 
- check the suction depth. 

 

 

 

3.

 

The pump stops due 
to overheating 
caused by the 
opening of the 
thermal overheat 
protection. 

1) The power supply does no conform 
to  that  on  the  rateing  plate  of  the 
motor (voltage to high or to low) 
2)  A  soild  object  has  blocked  the 
impeller 
3)  The  pump  has  been  operating  with 
water that is too hot. 
4)  The  pump  ran  dry  or  ran  with  the 
delivery  tap  closed  for  more  than  10 
minutes. 

1)  -  4)  remove  the  plug,  remove  the  cause  of 
overheating,  wait  for  the  motor  to  cool  down  and 
start it again. 

 

 

 

 

 

 

 
 

 

 

Содержание LEADER ECOTRONIC Series

Страница 1: ...INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE ECOTRONIC ECOPLUS ECOTRONIC INOXPLUS...

Страница 2: ......

Страница 3: ...multi impller surface pumps 1 2 2 Electronic boosters with external devices to prevent dry running 1 2 3 Boosters with integrated electronics 1 2 4 Boosters with tank for domestic water supplies 2 3 S...

Страница 4: ...ort service in order to avoid all risks Overload protection The pump has a thermal overload safety device In the event of any overheating of the motor this device automatically switches off the pump T...

Страница 5: ...for the first time If the pump is installed above the water level filling must be performed slowly until the water overflows wait a few seconds to make sure that all the air has escaped and top up un...

Страница 6: ...must not exceed 28 psi The pump will not operate if the tap is over 50 feet above the level of the pump The electronic device is fitted on the delivery side of the pump by connecting the 1 male connec...

Страница 7: ...olled pumps The pump must never be allowed to run dry The diameter ot the suction and delivery hoses must not be less than the relative inlet or outletof the pump 1 A hose with a greater diameter shou...

Страница 8: ...not submerged in the water suction valve blocked the maximum suction depth has been exceeded 1 stop the pump unscrew the delivery pipe shake the pump and suction hose to remove any air bubbles Top up...

Страница 9: ...is product or its parts must be disposed of in accordance with the laws regarding the environment Use the local public or private refuse collection services 7 GUARANTEE Any material or manufacturing d...

Страница 10: ...7 DAB PUMPS INC 3226 BENCHMARK DRIVE LADSON SC 29456 USA TEL 1 843 797 5002 FAX 1 843 797 3366...

Отзывы: