Daavlin 1 Series Скачать руководство пользователя страница 14

Proprietary and Confidential. Printed copies will not be updated. 

MNL-00049 [1] 

Page 

14

 of 

19

 

 

DO NOT REPLACE LAMPS INDIVIDUALLY.  ALL LAMPS SHOULD BE REPLACED AT THE 
SAME TIME TO AVOID UNEVEN TREATMENTS OR ERYTHEMA.  PLEASE CONTACT THE 
DAAVLIN  SERVICE  DEPARTMENT  PRIOR  TO  REPLACING  THE  LAMPS  TO  OBTAIN 
IMPORTANT INFORMATION ON HOW THE OUTPUT OF THE UNIT WILL BE AFFECTED BY 
THE CHANGE.   

Because of differences between brands, always replace lamps with the same brand as originally 
installed.  Consult the 6.1 

Lamp Specification Guide

 on page 4 for replacement lamp guidance 

and contact the Daavlin service department for a lamp replacement quote.  They can be reached 
by dialing 1-800-322-8546 or via email at [email protected]. 

15.3.1 Lamp Replacement 

1.  First, unplug the device, then, using a Phillips head screwdriver, remove the two screws 

located on each side of the device.  Then, 

2.  Lift off the top of the device to expose the lamps.  
3.  On each lamp there are two clear plastic clasps that hold the lamps in position. To remove 

them position both thumbs on the top of the clasp and use your index fingers to pull the 
sides of the clasp outward until it releases, and the clasp can be removed.  

4.  On top of each lamp socket there will be a red button that, when pushed, will allow you to 

remove the base of the lamp from its corresponding lamp socket. With one hand firmly 
press and hold the red button down. While holding the red button down use your other 
hand to carefully lift the lamp up and out of the socket.  

5.   With one hand near the base of the lamp and the other at the opposite end, grasp the 

lamp and pull both ends upward at the same time until it clears both clasps and the lamp 
holder/socket.  

6.  To replace the lamps in their lamp-holders, press the base of the lamp straight down.  A 

distinctive snapping sound will be heard which indicates that the lamp is properly seated. 

7.  Once reassembled, reset the lamp hours to zero.  

15.3.2 Resetting Lamp Hours  

When changing lamps, 

it is important to reset the lamp age to zero so the new lamp’s 

operational hours can be tracked. Please contact the Daavlin service department for 
instructions on resetting the 

device’s lamp hours. 

16.0 

Environmental Specifications 

The 1 Series should be used in an electromagnetic environment as described below. 
 

Table 3 Electromagnetic Emissions 

Emissions Test 

Conformity  EMC Environment Guide 

RF Emission Following 

CISPR 11 (EN 55011) 

Group 1 

Test unit only radiates RF energy for 
internal use in powering lamps, and it 
seems unlikely that nearby medical 
devices would be affected.  

Содержание 1 Series

Страница 1: ...MNL 00049 1 Proprietary and Confidential Page 1 of 19 DT Home Control Operation Manual Modes of Operation Timed Mode...

Страница 2: ...10 3 How to Position Yourself 10 11 0 Setting Up a Treatment Time 10 12 0 Viewing Device Code for Flex Rx 11 13 0 Enable Disable Refill FlexRX 11 13 1 Refill FlexRx 12 14 0 Special Notes 12 15 0 Care...

Страница 3: ...have prescribed your device with FlexRx a system that limits the total number of exposures the device will deliver Specific information about these systems is provided in this manual 2 0 Indications...

Страница 4: ...vice department to determine an appropriate replacement 5 0 Unpacking and Assembly 1 Open the top of the box and grasp both sides of the device Pull it out of the box along with the foam packers on ea...

Страница 5: ...kin that the physician does not intend to treat During extremely long treatments some surfaces may become hot Remove any body parts from those surfaces if it becomes uncomfortable The unit should have...

Страница 6: ...0 Environmental Specifications If the device continues to malfunction cease operation and contact the Daavlin Service Department If necessary operation of equipment may be terminated by disconnecting...

Страница 7: ...ee page 21 DT Controlled Phototherapy Devices are considered CISPR Group 1 Class A devices to be used for prescription use only 8 0 Operating Specifications Ambient Temperature 15 C to 30 C 59 F to 86...

Страница 8: ...a prominent and easily readable position Please read the label carefully as it contains important safety information Figure 2 Warning Label Figure 3 Identification Label The following table lists all...

Страница 9: ...treatments along with any other notes regarding your treatment or treatment results For example forgot lip balm put sunscreen on tender area etc Note A free printable treatment log is available for d...

Страница 10: ...e on the acrylic surface Excess pressure can cause the acrylic surface to crack and break Larger Area Treatment Choose the 9 inches position when starting your therapy Position the 1 Series so that th...

Страница 11: ...n again will pause treatment 8 While paused pressing the CANCEL button will end the treatment and prompt a new treatment 12 0 Viewing Device Code for Flex Rx The Device Code is predetermined by the so...

Страница 12: ...ed When power is restored the controller will prompt for the Key Code and another treatment will have to be started a If Flex Rx is activated and the controller loses power during a treatment an expos...

Страница 13: ...leaners 2 Allow to air dry and inspect for visible contaminants 3 If contaminants remain repeat until no visible containments remain repeat steps 0 and 2 15 2 3 High Level Disinfection Follow a high l...

Страница 14: ...removed 4 On top of each lamp socket there will be a red button that when pushed will allow you to remove the base of the lamp from its corresponding lamp socket With one hand firmly press and hold th...

Страница 15: ...tual Level Electrostatic discharge immunity test following IEC 61000 4 2 8kV conductive surfaces coupling planes 2kV 4kV 8kV and 15kV non conductive surfaces 8kV conductive surfaces coupling planes 2k...

Страница 16: ...guidance Conducted RF IEC 61000 4 6 3 Vrms 150 kHz to 80 MHz 3 Vrms Portable and mobile RF communications equipment should be used no closer to any part of the device including cables than the recomm...

Страница 17: ...elephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF tran...

Страница 18: ...with our operating instructions The Limited Warranty does not apply to Equipment failure or damage caused by shipping or customer abuse misuse or accident incorrect customer installation improper ele...

Страница 19: ...d warranty service work However this Limited Warranty will be declared null and void if non qualified technicians perform any repair or maintenance on the Equipment unless prior written authorization...

Отзывы: