VNE Vacuum Tube Compression Amplifier
HAZELRIGG INDUSTRIES
19
Although the tube filament is rated for 12.6 volts, utilization of 12.0 volts has no effect on the
operation of the VNE.
Low-voltage Supplies
This supply provides +15, -15, and +5 volts for the solid-state circuitry in the Pulse Width
Modulator.
B+
supply
Two separate regulated voltages are required for the plates of the VNE. The B+ is filtered with
long-life, low-leakage computer-grade filter capacitors before being regulated and extensively
bypassed and decoupled. The negative side of the supply is grounded.