DXS-3600 Series 10GbE Layer 2/3 Switch Hardware Installation Guide
5
Please refer to the “
LED Indicators
” section in the
Appendix A
for more LED information.
Rear Panel Description
Located on the rear panel of the switch are
two power supply module slots
and
three fan module slots
.
One power
supply module
and
three fan modules
are included in the package for this switch. Any additional power supply
module or fan module needs to be bought separately. This switch also supports the use of a DC power supply module.
Figure 1-5 Rear panel view of the DXS-3600-16S
Figure 1-6 Rear panel view of the DXS-3600-32S
Ports that can be found on the rear panel of this switch are listed in the table below.
Link/Act LEDs
This LED will light solid green when there is a secure connection to a 10Gbps
Ethernet device at any of the ports.
This LED will light solid orange when there is a secure connection to a 1Gbps
Ethernet device at any of the ports.
This LED will blink green when a 10Gbps port is active, or blink orange when a
1Gbps port is active.
This LED will be off when there is no link or activity.
Stacking ID
This 7-segment LED can display numbers from 1 to 12 and the following letters H, h,
E, and G. The stacking ID (1 to 12) can be assigned manually by the user or
automatically by the system.
The letter ‘
H
’ will be displayed if this switch is the
master switch
in the stack.
The letter ‘
h
’ will be displayed if this switch is the
backup master switch
in the
stack.
The letter ‘
E
’ will be displayed if there was an error in the system’s self-test.
The letter ‘
G
’ will be displayed when the
Safeguard
engine entered the
exhausted
mode
.
Port
Description
Two Power Supply Module
Slots
These slots can be equipped with 4 kinds of additional modules. Only one power
supply module is included. Any additional modules should be bought seperately.
• DXS-3600-PWR-FB
(300 Watt, AC PSU tray with Front-to-Back airflow)
• DXS-3600-PWR-BF
(300 Watt, AC PSU tray with Back-to-Front airflow)
•
DXS-3600-PWRDC-FB
(300 Watt, DC PSU tray with Front-to-Back airflow)
Three Fan Module Slots
These slots can be equipped with 2 kinds of additional modules. These modules are
not included and should be bought seperately.
•
DXS-3600-FAN-FB
(Normal fan tray with Front-to-Back airflow)
•
DXS-3600-FAN-BF
(Normal fan tray with Back-to-Front airflow)
LED
Description
FA N 1
FA N2
FA N 3
100-240 VAC
50-60H z
1.7 A MAX
4.0 A
or
PO WE R 1
100-240 VAC
50-60Hz
1.7 A MAX
4.0 A
or
POWER 1
FA N 1
FA N 2
FA N 3
100-240 VAC
50-60Hz
2.3 A MAX
5.2 A
or
POWER 1
100-240 VAC
50-60Hz
2.3 A MAX
5. 2 A
or
POWER 1
Содержание DXS-3600-16S
Страница 1: ...Hardware Installation Guide Product Model DXS 3600 Series Layer 2 3 Managed 10GbE Switch Release 1 10 ...
Страница 35: ...DXS 3600 Series 10GbE Layer 2 3 Switch Hardware Installation Guide 29 Warranty ...
Страница 36: ...DXS 3600 Series 10GbE Layer 2 3 Switch Hardware Installation Guide 30 Technical Support ...