22
DWL-8220AP User’s Manual
D-Link Systems, Inc.
Installation (continued)
Installation
Solid Wall or Ceiling Installation
Note. The solid surface mounting option requires CAT5 cable that does not have strain relief,
unless you plan to route the cable through a hole in the wall or ceiling. The other options can
use CAT5 cable with or without strain relief.
1.
Prepare holes in the wall or ceiling for the universal mounting bracket, using the following
steps:
a.
Place the paper mounting template over the location where you want to install the
access point.
b.
Mark the screw hole location(s).
• If you plan to route the CAT5 cable externally along the wall or ceiling, mark
the locations of both the center screw hole and the screw hole by the port
connector opening.
• If you plan to route the CAT5 cable through a hole in the wall or ceiling, mark
the location of the center screw hole only. You cannot use the screw hole by the
port connector opening if you cut a hole for the opening.
Note:
Do not mark the four holes on the edges of the bracket. These are the holes
indicated by the dashed lines on page 20. The access point fits into these holes.
They are not screw holes.
c.
Remove the template.
2.
Install the drywall anchor(s):
a.
Hammer a drywall anchor into each hole, up to the beginning of the threads on
the anchor.
b.
Screw each anchor the rest of the way into its hole using a #2 Phillips-head
screwdriver.
c.
Remove the screw from each anchor and save the screw(s) for step 6 on page
20.
3.
Unlock the universal mounting bracket from the access point by inserting the 3-mm or
1/8-inch screwdriver into the Unlock hole on the access point as shown below.
Note:
To avoid damage to the access point’s lock mechanism or electronic components, do
not use excessive force when inserting a tool into the Unlock or Lock hole.