Grounding the Switch

This step must be completed before powering on 

the switch.

Required tools and equipment for grounding

•  Grounding screw (included) and one M4x6 

(metric) pan-head screw (not included).

•  Grounding cable (not included). The grounding 

cable should be sized according to local and 

national installation requirements. Depending 

on the power supply and system, a 12 to 6 AWG 

copper conductor is required for installation. 

Commercially available 6 AWG wire is 

recommended. The length of the cable depends 

on the proximity of the switch to proper 

grounding facilities.

•  A screwdriver (not included).

Note: 

Verify that the system is powered off.

1.  Remove the grounding screw from the back of 

the device and place the #8 terminal lug ring of 

the grounding cable on top of the grounding 

screw opening.

2.  Insert the grounding screw back into the screw 

opening and use a screwdriver to tighten the 

grounding screw.

3.  Attach the terminal lug ring at the other end 

of the grounding cable to an appropriate 

grounding source.

4.  Verify that the connection between the 

grounding connector on the switch and the 

grounding source is secure.

Powering On the Switch

1.  Connect the power cord to the power connector 

on the switch.

2.  Plug the other end of the power cord into a 

nearby power socket.

Connecting to the Network

The switch can be integrated into the network 

through one of the following connection methods:

Switch to End Node or Powered Device

Use a standard Ethernet cable to connect the switch 

to PCs with an 10/100/1000 Mbps RJ-45 interface, 

or connect and power remote IEEE 802.3af/at-

compliant devices, such as IP cameras or IP phones 

using PoE.

Switch to Hub or Switch

Connect the switch to another switch or hub using 

the RJ-45 or SFP uplink ports.

Switch to Server

Connect the switch to a network backbone or 

network server using the RJ-45 or SFP uplink ports.

Additional Information

For additional support, please refer to the user 

manual, or visit 

http://support.dlink.com/

 which 

will direct you to your local D-Link support website.

Содержание DSS-100E-18P

Страница 1: ...vailable on the D Link website This document will guide you through the basic installation process for your new D Link 18 Port Unmanaged PoE Switch DSS 100E 18P Quick Installation Guide КРАТКОЕ РУКОВОДСТВО ПО УСТАНОВКЕ 17 18 ...

Страница 2: ...witch Table 3 Before You Begin This Quick Installation Guide gives you step by step instructions for setting up your DSS 100E 18P 18 Port Unmanaged PoE Switch The model you have purchased may appear slightly different from the one shown in the illustrations For more detailed information about the switch please refer to the User Manual Package Contents This DSS 100E 18P package should include the f...

Страница 3: ... for the acceptable operating temperature and humidity ranges Install the switch in a site free from strong electromagnetic sources vibration dust and direct sunlight Leaveatleast10cmofspacetotheleftandright hand side of the switch for ventilation Visually inspect the power connector and make sure that it is fully secured to the power cord Do not stack any devices on top of the switch Using the Sw...

Страница 4: ...ttach the terminal lug ring at the other end of the grounding cable to an appropriate grounding source 4 Verify that the connection between the grounding connector on the switch and the grounding source is secure Powering On the Switch 1 Connect the power cord to the power connector on the switch 2 Plug the other end of the power cord into a nearby power socket Connecting to the Network The switch...

Страница 5: ...новки совместимого SFP трансивера Таблица 2 Компоненты задней панели Рисунок 3 Компонент Описание 1 Switch GND Винт заземления предназначен для крепления клеммы заземляющего провода к коммутатору 2 Разъем питания Разъем предназначен для подключения кабеля питания Таблица 3 Неуправляемый коммутатор с 16 портами 10 100Base TX 1 портом 10 100 1000Base T и 1 комбо портом 100 1000Base T SFP 16 портов P...

Страница 6: ...тимым значением температур и влажности Установитекоммутаторвместе защищенномот воздействиясильныхэлектромагнитныхполей вибрации пыли и прямых солнечных лучей Оставьтенеменее10смсвободногопространства слеваисправаоткоммутаторадляобеспечения вентиляции Осмотрите кабель питания и убедитесь в безопаснос ти его подк лючения к соответствующему разъему на задней панели коммутатора Не размещайте никаких у...

Страница 7: ...тания коммутатора Подключите кабель питания к соответствующему разъему на задней панели коммутатора и к электрической розетке Подключение коммутатора к сети Коммутатор можно подключить к сети одним из следующих способов Подключение коммутатора к конечному узлу или питаемому устройству Для подключения коммутатора к компьютеру с сетевымадаптером10 100 1000Base Tсразъемом RJ 45 используйте стандартны...

Страница 8: ...02 3at Порты с поддержкой PoE Порты 1 16 Бюджет мощности PoE 230 Вт макс 30 Вт на порт PoE Физические параметры Размеры Д x Ш x В 440 x 178 x 44 мм Вес 2 137 кг Условия эксплуатации Питание 100 240 В переменного тока 50 60 Гц Потребляемая мощность Максимальная потребляемая мощность 265 Вт функция PoE включена 16 89 Вт функция PoE выключена Потребляемая мощность в режиме ожидания 9 63 Вт 240 В MTBF...

Страница 9: ...арактеристиках устройства Не вскрывайте корпус устройства Перед очисткой устройства от загрязнений и пыли отключите питание устройства Удаляйте пыль с помощью влажной салфетки Не используйте жидкие аэрозольные очистители или магнитные статические устройства для очистки Избегайте попадания влаги в устройство Устройство должно также быть заземлено если это предусмотрено конструкцией корпуса или вилк...

Страница 10: ...ер ООО Д Линк Трейд 390043 г Рязань пр Шабулина д 16 Тел 7 4912 575 305 Россия Москва Графский переулок 14 Тел 7 495 744 00 99 E mail mail dlink ru Україна Київ вул Межигірська 87 А Тел 38 044 545 64 40 E mail ua dlink ua Moldova Chisinau str C Negruzzi 8 Tel 373 22 80 81 07 E mail info dlink md Беларусь Мінск пр т Незалежнасці 169 Тэл 375 17 218 13 65 E mail support dlink by Қазақстан Алматы Құрм...

Отзывы: