DSN-5000 series Hardware Reference Guide
29
3. Save the shipping container, foam, and antistatic bags in case you have to return the
DSN-5000-10 expansion array. Returning the DSN-5000-10 expansion array in any other
container is not advised.
4. Check the contents against the items referenced on the packing list. If any item is
missing or damaged, notify a sales representative and/or the shipping agency.
4.5 Items Supplied by the User
Table 4-3 lists the additional items you must supply to perform the DSN-5000-10 expansion
array installation. All users must provide the items in the first row of Table 4-3. Rack-mount
users must provide the additional items shown.
Table 4-3. User-Supplied Items for Installing the DSN-5000 Expansion Array
User Category
User-Supplied Items
All Users
Two available AC outlets not controlled by a wall switch (for best results, the second power
receptacle should be on a different circuit).
Rack-Mount Users
A standard NEMA-compliant 19-inch rack (cables supplied for connections between the DSN-5000
series primary array and DSN-5000-10 expansion arrays require all arrays to be located in close
proximity to each other).
Additional mounting hardware for specific rack being used, if necessary.
4.6 Installing the DSN-5000-10 Expansion Array
If the DSN-5000-10 expansion array will be installed on a desktop or shelf, locate the array
close to the DSN-5000 series primary array, with sufficient ventilation space between the
expansion array and any other objects in the vicinity. Do not block the air vents on the front
and back of the DSN-5000-10 expansion array enclosure. Install the cables and power cords
according to the procedures in the following sections.
If the DSN-5000-10 expansion array will be mounted in a rack, mount the DSN-5000-10
expansion array in the same rack, either above or below the primary array. For information
about installing the system in a rack, refer to Appendix B and the documentation for the
rack.
The rack cabinet must provide sufficient airflow to the front and back of the
DSN-5000-10 expansion array to maintain correct cooling. It must include
ventilation sufficient to exhaust the heat generated by equipment installed
in the rack.
Содержание DSN-5210-10 - xStack Storage Area Network Array Hard...
Страница 8: ...viii Contents This Page Left Intentionally Blank ...
Страница 16: ...8 Chapter 1 Introduction This Page Left Intentionally Blank ...
Страница 24: ...16 Chapter 2 DSN 5000 Series Primary Array Layout This Page Left Intentionally Blank ...
Страница 48: ...40 Appendix A Replacing and Upgrading FRUs This Page Left Intentionally Blank ...