Chapter 3  Installing the DSN-3000 series Storage System 

 

This Page Left Intentionally Blank 

Содержание DSN-3400-10 - xStack Storage Area Network Array Hard...

Страница 1: ...xStack Storage TM D Link xStack Storage iSCSI SAN Array Managed SAN Solution DSN 3200 DSN 3400 Hardware Reference Guide Version 1 0 ...

Страница 2: ...o change without notice The only warranties for D Link products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty D Link shall not be liable for technical or editorial errors or omissions contained herein Copyright 2008 D Link Systems Inc Trademarks Adobe and Acrobat are tr...

Страница 3: ...s very possible that you will never need to replace it However should you need to replace it consult your service documentation Do not dispose of the battery along with household waste Contact your local waste disposal agency for the address of the nearest battery deposit site Following are the safety agency certifications that the xStack Storage enclosure has met CSA 60950 1 UL 60950 1 IEC 60950 ...

Страница 4: ...iv Document Revision Level Revision Date Notes Version 1 0 October 10 2008 ...

Страница 5: ... preceded by Cautions Cautions contain information which if not followed can cause damage to the xStack storage system They are preceded by Warnings Warnings contain information which if not followed can cause damage to the xStack storage system and to the person installing it They are preceded by Related Documentation In addition to this document the following documents are available from D Link ...

Страница 6: ... or by phone Tech Support for customers within the United States D Link Technical Support over the Telephone Please see our support site for current number http support dlink com Monday to Friday 8 00am 5 00pm PST PDT D Link Technical Support over the Internet http support dlink com Tech Support for customers within Canada D Link Technical Support over the Telephone Please see our support site for...

Страница 7: ...3 1 2 Desktop Floor or Shelf Installation 22 3 1 3 Rack mount Guidelines 23 3 2 Unpacking the DSN 3000 series Storage System 23 3 3 Items Supplied by the User 24 3 4 Connecting to the iSCSI Data Ports 25 3 4 1 Connecting to the DSN 3200 Host Network Connection Ports 25 3 4 2 Connecting to the DSN 3400 Host Network Connection Port 25 3 5 Connecting to the Management Port 26 3 6 Connecting the Power...

Страница 8: ...viii Contents This Page Left Intentionally Blank ...

Страница 9: ...r cache memory Eight 1GbE local area network LAN connectors DSN 3200 or one 10GbE connection DSN 3400 accessed via the back panel A 10 100 Mbps management port An RS 232 C DB9 diagnostic port for troubleshooting purposes Complete configuration and management are available through the intuitive graphical based xStack Storage Management Center For the latest information about supported drives consul...

Страница 10: ...rotection and reduced training costs Scalability over long distances ideal for remote data replication and disaster recovery Three internal fans provide cooling Battery pack ensures that a charged battery is on hand to preserve buffer cache contents if a power failure occurs Contents are backed up for approximately 72 hours 1 3 System Overview Figure 1 1 shows a typical DSN 3000 series storage sys...

Страница 11: ...N 3000 series Layout This chapter describes the hardware components on the DSN 3000 series storage system The topics covered in this chapter are Section 2 1 Front Panel Components Section 2 2 Back Panel Components Section 2 3 Side and Bottom Panel Components ...

Страница 12: ...3000 series is ready for operation or encountered a fault condition see Figure 2 1 and Table 2 1 A lock on the bezel that protects access to the drives inside the unit The hard drive power and drive activity fault LEDs see Figure 2 1 and Table 2 2 Figure 2 1 Front View of the DSN 3000 Series Storage System When installed the front bezel uses pipes to pass light from the LEDs behind it to the front...

Страница 13: ...ff or performing its Power On Self Test Red ON a fault has occurred Boot and Fault Green ON normal operation Table 2 2 Hard Drive LEDs for each drive 0 through 14 LED Color Description Drive Power Blue ON Drive is powered and operational Green Blinking Data being transmitted or received from corresponding SATA drive Drive Activity and Fault Red ON Drive has experienced a fault and is offline ...

Страница 14: ...right of the iSCSI data ports This requires a female to female straight through cable provided with the system see Figure 2 4 for the DSN 3200 and Figure 2 6 for the DSN 3400 Management port Mgmt 10 100 one 10 100 RJ 45 management is located to the right of the diagnostic port The management port has port speed and port activity LEDs see Figure 2 2 Figure 2 4 and Figure 2 6 Power switch and reset ...

Страница 15: ... Table 2 3 identifies the switches and their function Figure 2 3 Power and Reset Switches Table 2 3 Power and Reset Switches Function Switch Description Power Applies power to the xStack Storage Array Pressing this switch for longer than 3 seconds removes power from the xStack Storage Array and turns off the unit Reset Resets the xStack Storage Array ...

Страница 16: ...torage DSN 3200 enclosure Figure 2 4 External Interfaces on the xStack Storage DSN 3200 Enclosure 2 2 2 2 DSN 3200 LEDs Each RJ 45 host network connection on the back of the xStack Storage DSN 3200 enclosure has two bicolor light emitting diode LED indicators that show the activity and speed for that port Table 2 4 describes the host network connection LED indicators on the back of the xStack Stor...

Страница 17: ... port LEDs and Figure 2 5 shows their location Table 2 5 Management Port LED Indicators on the xStack Storage DSN 3200 Enclosure Color Description Green ON Link is operational Green Blinking Data is being transmitted or received on the RJ 45 port Yellow OFF Connection has been established at 10 Mbps Yellow ON Connection has been established at 100 Mbps Figure 2 5 Management Port LED Locations ...

Страница 18: ...rnal Interfaces on the xStack DSN 3400 Enclosure 2 2 2 4 DSN 3400 LEDs Two LEDs next to the XFP connector show transmit Tx and receive Rx activity on the host network interface Table 2 6 describes the Tx and Rx LED indicators on the back of the xStack DSN 3400 enclosure Table 2 6 Host Network Connection LED Indicators on the xStack DSN 3400 Enclosure LED Color Description OFF There is no transmit ...

Страница 19: ...nection has been established at 10 Mbps Activity Link Yellow ON Connection has been established at 100 Mbps OFF Data is being sent or received at 10 Mbps Port Speed Yellow Data is being sent or received at 100 Mbps 2 2 3 Rear Vents Figure 2 2 shows air vents that allow the exit of air through the rear of the chassis Please be sure these vents are not blocked 2 3 Side and Bottom Panel Components Th...

Страница 20: ...20 Chapter 2 DSN 3000 series Layout This Page Left Intentionally Blank ...

Страница 21: ...ge system The topics covered in this chapter are Section 3 1 Site Considerations Section3 2 Unpacking the DSN 3000 Series Storage System Section 3 3 Items Supplied by the User Section3 4 Connecting to the iSCSI Data Ports Section 3 5 Connecting to the Management Port Section 3 6 Connecting the Power Cords Section 3 7 Powering on the DSN 3000 series Storage System ...

Страница 22: ... outlet within six feet 1 82 meters of the DSN 3000 series storage system The location should allow for at least six inches 152 3 mm of space at the front and back of the DSN 3000 series storage system for ventilation Do not place the DSN 3000 series storage system next to on top off or below any device that generates a significant amount of heat or will block the fee flow of air through the DSN 3...

Страница 23: ...e air flow clearances specified in this guide must be maintained within the rack The AC supply circuit for rack mounted equipment must be capable of supplying the total current specified on all the labels of the rack mounted equipment All AC power supply connections must be properly grounded To ensure the integrity of the earth connection special attention must be given to connections that are not...

Страница 24: ...hernet cable If you want to use the DSN 3000 series storage system s Link Aggregation feature the switch must support LAGs DSN 3200 Users An IP address for each DSN 3200 storage system host connection RJ 45 data port that will connect to your SAN An Ethernet cable for each DSN 3200 storage system host connection RJ 45 data port that will connect to your SAN the DSN 3000 series storage system auto ...

Страница 25: ...etwork connection port 0 on the DSN 3200 storage system back panel see Figure 2 4 Connect the other end of the cable to your SAN or host system 2 To connect additional host network connection ports to your SAN repeat step 1 using another Ethernet cable and the next available DSN 3200 storage system port in sequence port 1 then port 2 and so on Do not skip ports when making these connections 3 4 2 ...

Страница 26: ...4 for the DSN 3200 and Figure 2 6 for the DSN 3400 Do not connect one NIC to the management and host network connection ports Connect one NIC to the management port and connect another NIC in the same PC or a different PC to the host network connection port s 3 6 Connecting the Power Cords The DSN 3000 series storage system has a three power receptacles All three must be used to connect the DSN 30...

Страница 27: ...n Process If the DSN 3000 series Storage System Verify the Power on Process by Has no front panel Ready Fault LED Wait five minutes after powering on the DSN 3000 series storage system Has a front panel Ready Fault LED The LED turns green when the startup process completes If the LED turns red reboot the DSN 3000 series storage system If the problem persists contact Technical Support Diagnostic po...

Страница 28: ...28 Chapter 3 Installing the DSN 3000 series Storage System This Page Left Intentionally Blank ...

Страница 29: ...s A 1 Installing the Battery Pack The xStack Storage Array accommodates a 4 cell or 6 cell shrink wrapped battery pack Because write back caching is always enabled we recommend you have a battery to back up the buffer cache contents To install a battery in your xStack Storage SAN Array follow these steps 1 Hold the battery as shown to align the fastener pad Make sure the battery cable and connecto...

Страница 30: ...mly as shown in Figure A 2 until you feel it lock into place Figure A 2 Press the Battery Down Firmly Until it Locks 3 Align the battery plug with connector J35 as shown in Figure A 3 and insert it fully into the socket Figure A 3 Align the Battery Plug with Connector J35 ...

Страница 31: ...000 series Hardware Reference Guide 31 4 The connector locked firmly into connector J35 Figure A 4 Battery Plug Locked in Place 5 The installed battery is shown in Figure A 5 Figure A 5 The Installed Battery ...

Страница 32: ... with at least 512MB 2 x 256MB modules installed This should work well for most applications However several applications such as video streaming of the product could benefit from increased cache memory Please see Figure A 6 for buffer memory location Note on Memory The xStack Storage controller s system and buffer memory must be installed as matching pairs Table A 1 lists the specifications for D...

Страница 33: ...se 4 bit wide DRAMs do not provide DM signals and cannot be used Registered DIMMs must be registered as per the JEDEC specification for registered DIMMs Buffered DIMMs must be buffered as per the JEDEC specification for buffered DIMMs Organization Conforming DIMM organizations are shown in Table A 2 Table A 2 DIMM Organization DIMM 0 J38 System Memory Module DIMM 1 J39 System Memory Module Total S...

Страница 34: ...can be part of a volume that may or may not be redundant Before removing a drive from an operating xStack Storage Array make sure it is the correct one A 3 1 Drive and Tray Removal A drive tray assembly can be removed by pressing upwards on the green latch found on the tray and removing it with the handle as shown in Figure A 7 and Figure A 8 Figure A 7 Drive and Tray Removal Figure A 8 Remove Dri...

Страница 35: ... to install a hard drive in a drive tray 1 Remove the plastic air dam from the tray by squeezing the two levers together and lifting the piece out of the tray as shown in Figure A 9 Figure A 9 Removing the Plastic Air Dam Piece 2 Your tray should now look like Figure A 10 Figure A 10 Tray with Air Dam Removed ...

Страница 36: ...ard drive in tray as shown in Figure A 11 Figure A 11 Place Hard Drive in Tray 4 Align the mounting holes and insert four mounting screws to hold the drive securely in the drive tray as shown in Figure A 12 Figure A 12 Secure the Hard Drive in the Drive Tray ...

Страница 37: ... drive bay as shown in Figure A 13 Push the tray at the point indicated in Step 2 of Figure A 14 and push until it is seated firmly within the bay As you press you will see the tray handle begin to move inwards as the locking mechanism enters the locking slot When you see this then you must push the tray handle inwards as shown in Figure A 15 until you hear the green locking mechanism click Figure...

Страница 38: ...38 Appendix A Replacing and Upgrading FRUs Figure A 14 Press Here Until You See the Lever Move Inwards Figure A 15 Press Lever Inwards Until it Locks ...

Страница 39: ...eplaceable fans They can be replaced as follows 1 Locate the failed fan They can be identified by their green handle as seen in Figure A 16 Figure A 16 A User Replaceable Fan with Green Handle 2 Lift the handle grasp it and pull the fan upwards as seen in Figure A 17 Figure A 17 Lift the Handle and Pull Upwards ...

Страница 40: ...3 Remove the fan from its socket as seen in Figure A 18 Figure A 18 Remove the Fan 4 Insert the new fan by reversing the previous steps i e Insert fan into socket press firmly downwards until it is seated and lower the handle to lock it in place ...

Страница 41: ...ey can be replaced as follows 1 Locate the failed power supply module Unscrew the bolt holding the locking mechanism in place as shown in Figure A 19 Figure A 19 Unscrew the Bolt Holding the Locking Mechanism 2 Push the locking lever to the left and pull on the handle as shown in Figure A 20 Figure A 20 Push the Locking Lever to the Left and Pull Handle ...

Страница 42: ...as shown in Figure A 21 Figure A 21 Remove the Power Supply Module 4 Insert the new power supply module by reversing the previous steps i e Insert the new power supply module into the bay until it seats against the rear and the lever locks Then screw the locking bolt into place ...