Rack-mount Guidelines
The DSN-3000 series storage system can be mounted in a standard 19-inch rack. Observe the
following considerations for rack installations. For information about installing the system in
a rack, refer to the documentation for the rack.
All rack-mounting hardware must be carefully assembled to properly support the
equipment. Follow the instructions in the documentation for the rack.
The operating ambient temperature of rack-mounted equipment must not exceed the
maximum rated ambient temperature indicated in this guide.
The rack cabinet must provide sufficient airflow to the front and back of the DSN-3000
series storage system to maintain correct cooling. It must include ventilation sufficient
to exhaust the heat generated by equipment installed in the rack.
The rack must allow enough ventilation space between the DSN-3000 series storage
system and any other objects in the vicinity. Do not block the air vents on the front and
back of the DSN-3000 series enclosure. The air flow clearances specified in this guide
must be maintained within the rack.
The AC supply circuit for rack-mounted equipment must be capable of supplying the
total current specified on all the labels of the rack-mounted equipment.
All AC power supply connections must be properly grounded. To ensure the integrity of
the earth connection, special attention must be given to connections that are not
directly connected to the branch circuit (for example, power strips).
3.2
Unpacking the DSN-3000 Series Storage System
After receiving the DSN-3000 series storage system, perform the following steps to ensure
that it and other contents arrived safely.
1.
Inspect the outer shipping container for any damage that may have occurred in shipping.
Report any sign of damage to the appropriate shipping agency.
2.
Remove the DSN-3000 series storage system and cables from the shipping container.
3.
Save the shipping container, foam, and antistatic bags in case you have to return the
DSN-3000 series storage system. Returning the DSN-3000 series storage system in any
other container is not advised.
4.
Check the contents against the items referenced on the packing list. If any item is
missing or damaged, notify a sales representative and/or the shipping agency.
Содержание DSN-3400-10 - xStack Storage Area Network Array Hard...
Страница 4: ...iv Document Revision Level Revision Date Notes Version 1 0 October 10 2008 ...
Страница 8: ...viii Contents This Page Left Intentionally Blank ...
Страница 20: ...20 Chapter 2 DSN 3000 series Layout This Page Left Intentionally Blank ...
Страница 28: ...28 Chapter 3 Installing the DSN 3000 series Storage System This Page Left Intentionally Blank ...