DIS-200G Series Layer 2 Gigabit Industrial Smart Managed Switch Hardware Installation Guide
24
Figure 4-1 COM port Configuration
To be able to view the boot procedure, the switch needs to be rebooted. The simplest way, at this stage, to reboot the
switch is to unplug and re-insert the power cable from and into the power receptacle on the back of the switch or
terminal block on the top of the switch.
After correctly configuring the terminal settings and re-inserting the power cable, the boot procedure will appear in the
terminal.
3 tests completed successfully
RedBoot> fis load –d managed
Image loaded from 0x80040000-0xB12d1d30
RedBoot> go
Press ENTER to get started
After the boot sequence has been completed, the console login screen will be displayed.
Connecting to the Switch for the First Time
The switch supports user-based security that can prevent unauthorized users from accessing the switch or changing
its configuration. This section will explain how to log into the switch’s Command Line Interface via the out-of-band
console connection.
DIS-200G-12PS/12PSW PoE GE Switch
Command Line Interface
Firmware: Build 1.00.B032
Copyright © 2017 D-Link Corporation. All rights reserved.
User Access Verification
Username: