Troubleshooting
145
Troubleshooting
This chapter contains some problems you may run into when using
your router. After each problem description, we have provided
some instructions to help you diagnose and solve the problem.
Problems Starting Up the DI-106 or DI-106M
None of the LEDs are on when you power up the router
♦
Check the power cord and the power supply and make sure it
is properly connected to your DI-106 or DI-106M. If the
error persists you may have a hardware problem. In this case
you should contact technical support.
Connecting the RS-232 cable, cannot access the SMT
♦
Check to see if the DI-106 or DI-106M is connected to your
computer’s serial port.
♦
Check to see if the communications program is configured
correctly. The communications software should be configured
as follows:
◊
VT100 terminal emulation.
◊
9600 Baud rate.
◊
No parity, 8 Data bits, 1 Stop bit.