D-Link DGS-6600 Series Chassis Switch 

u

  9

EN

G

LIS

H

Management Options

The system may be managed out-of-band 

through the console port(s) and Ethernet port on 

the Control Module or in-band using Telnet/SSH. 

Each Switch must be assigned its own IP address, 

which is used for communication with an SNMP 

network manager or other TCP/IP application (for 

example BOOTP, TFTP). The Switch’s default IP 

address is 10.90.90.90 (out-of-band IP address). 

The user can change the default IP address 

to meet the specifications of your networking 

address scheme.

Connecting the Console Port (USB or 9 Pin 

D-Sub)

The switch provides a USB or 9 Pin D-Sub 

Serial Connection to a computer or terminal for 

monitoring and configuration. To use the console 

port, you need the following equipment:
•  A terminal or a computer with a  9 pin serial 

port /USB port and the ability to emulate a 

terminal.

•  A null modem or cross-over RS-232 cable 

with a female DB-9 connector for the switch’s 

console port.

- or -

•  A USB cable (with a Type B USB connector 

for the switch’s USB console port) and the 

Serial USB driver installed on the computer 

used to connect to the console.

Download the USB-Serial Driver here:

http://www.prolific.com.tw/eng/

downloads.asp?ID=31

Confirm the driver for your Operating 

System is for the X chip series.

To connect a terminal to the console port

1.  Connect the supplied RJ-45-to DB-9 

adapter cable to the standard 9-pin serial 

port on the PC. Connect the other end of 

the cable to the console port on the switch. 

Set the terminal emulation software as fol-

lows:

•  Baud rate: 115200

•  Data bits: 8

•  Parity: None

•  Stop bits: 1

•  Flow control: None

2.  Select VT100 for the terminal emulation 

mode.

3.  After you have correctly set up the 

terminal, plug the power cable into the 

power sup plies on the switch. The boot 

sequence will appear in the terminal.

4.  Press the Enter key at the password 

prompts. There is no default password for 

the Switch.

5.  Enter the commands to complete your 

desired tasks. Many commands require 

administrator-level access privileges. See 

the CLI Reference Guide on the documen-

tation CD for a list of all commands and 

additional information using the CLI.

Telnet Management

 Users may also access 

the switch CLI by using PC’s Command Prompt. 

To access it from your computer, users must 

first ensure that a valid connection is made 

through the Ethernet port of the Switch and 

your PC, and then click Start > Programs > 

Accessories > Command Prompt on your 

computer. Once the console window opens, 

enter the command telnet 10.90.90.90 

(depending on configured IP address) and 

press Enter on your keyboard. You should be 

directed to the opening console screen for 

the CLI of the switch, press the Enter key at 

the password prompts. There is no default 

password for the Switch.  

SNMP-Based Management

You can manage the Switch with D-Link 

D-View or any SNMP-compatible console 

program. The SNMP function is disabled by 

default for D-Link managed switches.

Additional Information

If you are encountering problems setting up 

your network, please refer to the User’s Guide 

that comes with the switch. It contains many 

more rules, charts, explanations and examples 

to help you get your network up and running. 

Содержание DGS-6600 Series

Страница 1: ...ough the basic installation process for your new D Link chassis based Switch Building Networks for People DGS 6600 Series Documentation also available on CD and D Link Website Quick Installation Guide...

Страница 2: ...ustry standard compliance the switch provides scalable expansion and a high level of investment protection for businesses and telecom carriers to deploy Gigabit and 10 Gigabit packet switching and rou...

Страница 3: ...tronic equipment 2 Use appropriate dust prevention measures 3 Maintain the required humidity in the operating environment 4 Always wear an anti static wrist strap when working around any electronic ci...

Страница 4: ...ay 84 6 288 DGS 6600 PWR AC Power Supply 853 5 110VAC or 220 VAC 2912 4 110VAC or 220 VAC Figure 2 Grounding of the DGS 6600 series Note All grounding conductors should be connected before the AC powe...

Страница 5: ...tem Ensure that the cabinet is durable enough to bear the weight of the DGS 6604 8 and its installation accessories Ensure that the dimensions of the cabinet provide enough space for the installation...

Страница 6: ...to the digital bar Figure 6 Ground Connections on the back of the DGS 6600 series chassis switch Precautions The sectional area of the grounding cable min of 18AWG should be selected to safely conduc...

Страница 7: ...nection 1 Connect the RJ45 connector of an Ethernet cable to the Ethernet port of the Switch s management module DGS 6600 CM or DGS 6600 CM II and connect the other end of the cable to any TCP IP capa...

Страница 8: ...et has been fastened completely and does not move or tilt Verify that the Power Supplies CM and Line Cards have been installed in the chassis 6 7 8 Verify that the optical fiber and twisted pair cable...

Страница 9: ...switch Set the terminal emulation software as fol lows Baud rate 115200 Data bits 8 Parity None Stop bits 1 Flow control None 2 Select VT100 for the terminal emulation mode 3 After you have correctly...

Страница 10: ...itches or Firewalls 0871 873 0909 09 00am 05 30pm BT 10ppm other carriers may vary Ireland Mon Fri All Products 1890 886 899 09 00am 06 00pm Sat 10 00am 02 00pm Phone rates 0 05ppm peak 0 045ppm off p...

Страница 11: ...striestandards bietet der Switch skalierbare Erweiterungsm glichkeiten bei hohem Investitionsschutz f r Unternehmen und Telekommunikationsbetreiber die Paketvermittlung und Routing ber Gigabit und 10...

Страница 12: ...gemessene Luftfeuchtigkeit vorherrschen 4 Tragen Sie bei der Arbeit an elektronischen Schaltkreisen immer ein Erdungsarmband 5 Fassen Sie Leiterplatten nur an den Kanten an Ber hren Sie keine Komponen...

Страница 13: ...g der Ger te der DGS 6600 Produktreihe Hinweis Alle Erdleiter m ssen angeschlossen sein bevor Wechselstrom den in dem Chassis Switch der DGS 6600 Produktreihe installierten Netzteilen zugef hrt wird D...

Страница 14: ...nien Installieren Sie den Switch nach M glichkeit in einem offenen Schrank Wenn der Switch in einem geschlossenen Schrank installiert wird ist auf eine ausreichende L ftung und W rmeableitung zu achte...

Страница 15: ...g unten zeigt die Installation des Netzteils Abbildung 5 Installation des Netzteils Anschlie en der Systemerdung An der R ckseite des DGS 6604 8 befindet sich ein GND Anschluss Betriebserdung GND muss...

Страница 16: ...Netzteils Vor dem Anschluss des Netzteils muss sichergestellt werden dass das im Lieferumfang enthaltene Netzteil zur existierenden Wechselstromversorgung passt Verwenden Sie nur ein Stromkabel mit e...

Страница 17: ...stallationspr fung Pr fliste f r die Installation Vergewissern Sie sich dass die externe Wechselstromversorgung die korrekte Spannung und Frequenz liefert Stellen Sie sicher dass der Schrank richtig f...

Страница 18: ...Sie sicher dass die Kabel sachgerecht angebracht und befestigt sind und keinerlei berbeanspruchungen ausgesetzt sind Stellen Sie sicher dass die Stromkabel sich in gutem Zustand befinden und alle Sic...

Страница 19: ...PCs an Schlie en Sie das andere Kabelende an den Konsolenport am Switch an Nehmen Sie in der Terminal Emulations Software folgende Einstellungen vor Baud rate Baudrate 115200 Data bits Datenbit 8 Par...

Страница 20: ...entreprises et aux soci t s de t l coms en vue de la commutation et du routage de paquets Gigabit et 10 Gigabit pour les mises en r seaux d entreprises et les services Internet aux particuliers reposa...

Страница 21: ...enez l humidit requise dans l environnement d exploitation 4 Portez toujours un bracelet antistatique si vous travaillez pr s de circuits lectroniques 5 Tenez un circuit imprim par ses bords Ne touche...

Страница 22: ...entation secteur DGS 6600 PWR 854 110 V CA ou 220 V CA 2913 110 V CA ou 220 V CA Figure 2 Mise la terre du DGS 6600 Remarque Tous les conducteurs de terre doivent tre connect s avant que le courant le...

Страница 23: ...ci apr s Installez le commutateur dans une armoire ouverte si possible Si vous installez le commutateur dans une armoire ferm e assurez vous que l armoire soit bien ventil e et quip e d un bon syst me...

Страница 24: ...ntation CA La proc dure d installation de l alimentation CA est illustr e sur le sch ma ci dessous Figure 5 Installation de l alimentation Mise la terre de l appareil Une masse de travail GND est inst...

Страница 25: ...Utilisez un c ble d alimentation avec un connecteur standard 3 broches pour le branchement lectrique Assurez vous que les contacts des c bles d alimentation branch s sont bien tablis Une fois le c bl...

Страница 26: ...fr quence correctes V rifiez que tous les l ments de l armoire sont bien fix s que rien ne bouge ou ne peut basculer V rifier que les alimentations le module de commande et les cartes de lignes ont t...

Страница 27: ...tion de terminal 3 Une fois que vous avez correctement configur le terminal branchez le c ble d alimentation dans les unit s d alimentation du commutateur La s quence de d marrage appara t sur le term...

Страница 28: ...e PC puis sur ce dernier cliquez sur D marrer Programmes Accessoires Invite de commandes Dans la fen tre de la console qui s ouvre entrez la commande Telnet 10 90 90 90 selon l adresses IP configur e...

Страница 29: ...sas y proveedores de telecomunicaciones con el fin de instalar conmutaci n y enrutamiento Gigabit y paquete de 10 Gigabit para conexi n en red de oficinas y servicios dom sticos de Internet basados en...

Страница 30: ...polvo 3 Mantenga la humedad necesaria en el entorno de funcionamiento 4 Lleve siempre una mu equera antiest tica cuando trabaje en las proximidades de los circuitos electr nicos 5 Sujete las placa de...

Страница 31: ...a tierra de la serie DGS 6600 Nota Todos los conductores de conexi n a tierra se deben conectar antes de que se aplique la alimentaci n de CA a las fuentes de alimentaci n de CA del conmutador modula...

Страница 32: ...ta las directrices siguientes Instale el conmutador en un bastidor abierto si es posible Si instala el conmutador en un bastidor cerrado aseg rese de que el bastidor dispone de buena ventilaci n y de...

Страница 33: ...alar la fuente de alimentaci n de CA se muestra en el diagrama siguiente Figura 5 Instalaci n de la fuente de alimentaci n Conexi n de la toma de tierra del sistema En la parte trasera del DGS 6604 8...

Страница 34: ...a fuente de alimentaci n Utilice un cable de alimentaci n con un conector est ndar de 3 pines para realizar la conexi n de alimentaci n Aseg rese de que los cables de alimentaci n conectados tienen un...

Страница 35: ...tilice las palancas del lateral izquierdo y derecho para empujar la placa en su sitio y apriete los dos tornillos en la placa utilizando un destornillador plano Precauci n 1 Tenga cuidado de no sujeta...

Страница 36: ...iones de su esquema de direcci n de conexi n en red Conexi n del puerto de la consola USB o D Sub de 9 pines El conmutador proporciona una conexi n serie USB o D Sub de 9 pines a un ordenador o termin...

Страница 37: ...aci n hacer clic en Inicio Programas Accesorios S mbolo del sistema en su ordenador Una vez abierta la ventana de la consola introduzca el comando telnet 10 90 90 90 en funci n de la direcci n IP conf...

Страница 38: ...lecomunicazioni per switching e routing di pacchetti Gigabit e 10 Gigabit per reti di aziende e uffici e servizi Internet su rete Ethernet per abitazioni Lo switch DGS 6604 offre in totale quattro slo...

Страница 39: ...tezione dalla polvere 3 Mantenere il livello di umidit richiesto nell ambiente operativo 4 Lavorando intorno alla circuiteria elettronica indossare sempre una fascetta antistatica da polso 5 Maneggiar...

Страница 40: ...10 VCA o 220 VCA Figura 2 Messa a terra dello switch della serie DGS 6600 Nota Tutti i conduttori di messa a terra devono essere collegati prima di alimentare gli alimentatori CA installati nello chas...

Страница 41: ...lo switch all interno di un armadio aperto Se lo switch installato all interno di un armadio chiuso verificare che l armadio sia dotato di un adeguato sistema di ventilazione e di dispersione del cal...

Страница 42: ...azione dell alimentatore CA Figura 5 Installazione dell alimentatore Collegamento a terra del sistema Sul retro del dispositivo DGS 6604 8 presente una connessione di messa a terra di lavoro GND La co...

Страница 43: ...collegamento utilizzare un cavo di alimentazione con connettore standard a 3 pin Verificare che i contatti dei cavi di alimentazione collegati siano adeguati Una volta collegato il cavo di alimentazi...

Страница 44: ...sca la tensione e la frequenza corrette Verificare che l armadio sia stato fissato completamente che non si muova o si inclini Verificare che gli alimentatori le schede CM e di linea siano state insta...

Страница 45: ...le per il monitoraggio e la configurazione Per utilizzare tale porta necessario quanto segue Terminale o computer dotato di porta USB seriale a 9 pin e della funzione per l emulazione di terminale Un...

Страница 46: ...90 90 a seconda dell indirizzo IP configurato e premere Invio sulla tastiera A questo punto comparir la schermata della console per la CLI Interfaccia della riga di comando dello switch premere Invio...

Страница 47: ...ices and patent markings if any To reduce the risk of bodily injury electrical shock fire and damage to the device and other equipment observe the following precautions Power Sources Observe and follo...

Страница 48: ...dentificaci n del producto u otras notificaciones incluyendo las notificaciones de copyright y marcado de patente si fuera el caso Para reducir el riesgo de lesiones personales descargas el ctricas in...

Страница 49: ...runnkr fur og a rar kr fur sem ger ar eru tilskipun 1999 5 EC Norsk Norwegian D Link Corporation erkl rer herved at utstyret er i samsvar med de grunnleggende krav og vrige relevante krav i direktiv 1...

Страница 50: ...an recycleerbare producten met lage toxiciteit in product en verpakking D Link raadt aan om steeds uw D Link producten uit te schakelen of uit de stekker te halen wanneer u ze niet gebruikt Door dit t...

Страница 51: ...milj ansvariga produkter och f rpackningar www dlinkgreen com Este s mbolo no produto ou embalagem significa que de acordo com as leis e regulamenta es locais este produto n o dever ser eliminado junt...

Страница 52: ...Ver 2 01 EU 2013 01 11 6DGS6600Q 02G...

Отзывы: