DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual
193
Precedence
header.
Time Range
Name
Tick the check box and enter the name of the Time Range settings that has been previously
configured in the
Time Range
Settings
window. This will set specific times when this access rule
will be implemented on the Switch.
Rx Rate (1-15624)
Use this to limit Rx bandwidth for the profile being configured. This rate is implemented using the
following equation: 1 value = 64Kbit/sec. (ex. If the user selects an Rx rate of
10
then the ingress
rate is 640Kbit/sec.) The user many select a value between
1
and
15624
or tick the No Limit
check box. The default setting is No Limit.
Counter
Specifies whether counter feature will be enabled/disabled
This is optional, the default is disabled.
If the rule is not binded with flow_meter, then all packet matched will be countered.
If the rule is binded with flow_meter, then “counter” here will be overrided.
Ports
Specifies the access rule will take effect on one port or a range of ports.
VLAN Name
Specifies the access rule will take effect on the VLAN Name specified.
VLAN ID
Specifies the access rule will take effect on the VLAN ID specified.
Click
Apply
to display the following
Access Rule List
window.
Figure 6 - 8 Access Rule List (Ethernet)
To view the configurations for previously configured rules click on the corresponding
Show Details
Button which will
display the following
Access Rule Details
window.
Figure 6 - 9 Access Rule Detail Information (Ethernet)
To create an
IPv4 ACL
select IPv4, enter the Profile ID and Profile Name into the top half of the screen in the
Add
ACL Profile
window and click
Select
the following window will appear.