DES-7200 Series Quick Installation Guide
3. An appropriate humidity is maintained.
4. Always wear an anti-static wrist strap when you touch any circuit board.
5. Try to hold a circuit board by its edges. Do not touch any components or the PCB.
6. Do not let any clothes touch a circuit board. An antistatic wrist strap can only prevent
static electricity from human damaging the circuit board, but cannot prevent any static
electricity on clothes.
System Grounding Requirements
A good grounding system is the basis for the stable and reliable operation of the
DES-7210/7206. It is the chief condition to prevent lightning stroke and resist interference.
Please carefully check the grounding conditions on the installation site according to the
grounding requirements, and perform grounding properly as needed.
Grounding of the DES-7210/7206
The system cables must ensure the normal working of the equipment. Before you connect
the cables, please carefully read the following precautions.
Power Requirements
When the DES-7210/7206 uses the AC power supply:
AC input voltage: 90Vac~264Vac, 47Hz~63Hz
Power: 1200W/2000W
When the DES-7210/7206 uses the DC power supply:
DC input voltage: DC - 36Vdc ~ -75Vdc
Power: 1200W/2000W
Please refer to following table to evaluate the total system requirement: