DES-7200 Series Quick Installation Guide 

3.    Tighten the screws on both sides of the power supply by using a straight screwdriver, 

as shown in Figure 3-7 and Figure 3-8. 

 

Installing the Power Supply of the DES-7210 and DES-7206 

Installing the Handle 

For easy handling of the system, the DES-7210/7206 chassis is provided with a handle, 
which can be installed by performing the following steps: 

1.    Align the handle with the sunk hole on the fastening bar; 

2.    Tighten the cross M4 sunk screws provided with the unit, as shown in Figure 3-9 and 

Figure 3-10. 

 

Installing the Handle of the DES-7210 and DES-7206 

 

10 

 

 

Содержание DES-7206

Страница 1: ...DES 7200 Series Quick Installation Guide ...

Страница 2: ...tion of this document in any form or by any means without the prior written consent of D Link Corporation is prohibited Exemption statement This document is provided as is The contents of this document are subject to change without any notice Please obtain the latest information through the D Link Corporation website D Link Corporation endeavors to ensure content accuracy and will not shoulder any...

Страница 3: ...ng the DES 7210 7206 into the Cabinet 8 Installing the Fan Tray 8 Installing the Power Supply 9 Installing the Handle 10 Installing the Cabling Rack of the DES 7210 11 Installing the Air Filter of the DES 7210 11 Connecting the System Ground 12 Connecting the DC Power Supply to the Power Module 12 Connecting the AC Power Supply to the Power Module 13 Connecting the Cable of the Management Module 1...

Страница 4: ......

Страница 5: ... for large scale network core backbone and heavy traffic node switch By expanding with high performance multi service cards the DES 7200 series switches support policy routing and IPV6 and satisfies customers flexible and complex application requirements Applications Core layers of such enterprise networks of educational financial and governmental organizations Running environment that needs power...

Страница 6: ... a long time the equipment may be damaged Temperature and Humidity Requirements of the DES 7210 7206 Temperature Relative Humidity Long term condition Short term condition Long term condition Short term condition 0ºC 45ºC 0ºC 45ºC 40 65 10 90 Note 1 The ambient temperature and humidity are measured at the point that is 1 5m above the floor and 0 4m before the equipment when there is no protective ...

Страница 7: ...peration of the DES 7210 7206 It is the chief condition to prevent lightning stroke and resist interference Please carefully check the grounding conditions on the installation site according to the grounding requirements and perform grounding properly as needed Grounding of the DES 7210 7206 The system cables must ensure the normal working of the equipment Before you connect the cables please care...

Страница 8: ...des 1 1 redundancy of power supply You are recommended to use multiple power supplies for the equipment to ensure its continuous and stable working by avoiding the impact of unexpected power failures on the equipment However you must note that the redundancy power supplies must be of the same type a mix of power supplies is not allowed Requirements of Installation Tools List of Installation Tools ...

Страница 9: ...at dissipation system Make sure that the cabinet is firm enough to bear the weight of the DES 7210 7206 and its installation accessories Make sure that the dimensions of the cabinet spare certain space for the installation of the front rear left and right panels of the DES 7210 7206 for the sake of heat dissipation The frame should be properly grounded Ventilation Requirements Following figure sho...

Страница 10: ...tray or the slide rail and push it into the cabinet 3 Fasten the DES 7210 7206 onto the cabinet with screws There are fastening notches on both the left and right of the front panel on the equipment frame Use screws to fasten them to the fastening bracket of the cabinet After fastened the equipment should be stable and still in the cabinet Installing the Fan Tray The DES 7210 7206 provides a venti...

Страница 11: ... following steps 1 Remove any blank panel of the power module by loosening the two cross screws with a cross screwdriver as shown in Figure 3 3 and 3 4 Installing the Power Supply of the DES 7210 and DES 7206 2 Insert the power supply module into the cabinet along the guide rail as shown in Figure 3 5 and Figure 3 6 Installing the Power Supply of the DES 7210 and DES 7206 9 ...

Страница 12: ...the DES 7210 and DES 7206 Installing the Handle For easy handling of the system the DES 7210 7206 chassis is provided with a handle which can be installed by performing the following steps 1 Align the handle with the sunk hole on the fastening bar 2 Tighten the cross M4 sunk screws provided with the unit as shown in Figure 3 9 and Figure 3 10 Installing the Handle of the DES 7210 and DES 7206 10 ...

Страница 13: ...er 2 Install the panel of the tracing rack by tightening the two captive screws with a straight screwdriver and the four cross screws with a cross screwdriver 3 Fasten the cabling rack by using the cross M3 screws provided The cabling rack is available in two sizes and you can select the appropriate one Installing the Cabling Rack of the DES 7210 Installing the Air Filter of the DES 7210 Simply pu...

Страница 14: ...rounding cable should be determined according to the possible maximum current Cables of good conductor should be used Do not use bare wire The grounding resistance for combined grounding should be less than 1Ω Simple Grounding Steps 1 Release the nut on the rear grounding post of the equipment 2 Lock the terminal of the grounding cable to the grounding pole 3 Tighten the nut 4 Connect the related ...

Страница 15: ...appropriate wiring posts You must ensure that the power cables connected are in good contact Simple Connection Steps 1 Remove the protection cover of the DC wiring terminal 2 Lock the power cable to the appropriate terminal according to the identification and tighten the pressing screw 3 Put on the protection cover and tighten the screw 4 Connect the other end of the power cable to the correspondi...

Страница 16: ... power cable to the corresponding socket or connector Connecting the Cable of the Management Module 1 Connect the end of the Ethernet cable with the RJ45 connector to the Ethernet port of the equipment management module 7210 7200 CM1 and the other end to the NM or control terminal 2 Connect the end of the standard DB9 serial cable with the RS 232 serial port to the RS 232 serial port of the equipm...

Страница 17: ...you plug unplug a PCB module use the ejector instead of forcedly Installation Check Verify if the external power supply matches the distribution panel of the cabinet After the equipment is installed check if the front back cabinet doors can be closed Verify that the cabinet has been fastened completely and does not move or tilt Verify that the equipment has been installed in the cabinet and all th...

Страница 18: ...ed AC or DC module Fan tray Antistatic hand ring Screwdriver Power cable for AC power configuration only Documentation 3 Module carton It contains the modules packing list and documentation of the DES 7210 7206 Note The above lists the items of a normal delivery which may differ from the actual delivery All depend on the purchasing contract Please check your goods carefully against the packing lis...

Отзывы: