Delete Trap:

 To delete previously defined SNMP Trap, press 

“Delete Trap”

 button, the Delete SNMP Trap Delete configuration window will pop out; 

checked the delete dialog box. Press 

“Apply”

 to delete the selected SNMP Trap setting. 

 

Figure 29.  Delete SNMP Trap 

Modify Trap:

 To modify previously defined SNMP Trap, click on the 

ID

 parameter to enter to the selected SNMP Trap to configure its community name, IP 

address and events. Press 

“Apply”

 to save change of the SNMP Trap. 

 

Figure 30.   Modify SNMP Trap 

 

Static MAC 

The Static MAC function allows you to enable the Switch to forward the data packets to specific MAC address and specific port. Only Static MAC function 
enabled ports will follow the Static MAC rule from the Static MAC list.  
 
Enabled / Disabled: Selecting the enable or disable Static MAC function on the Switch. Select “Enabled” to enabling the Static MAC function on the Switch, 
the Switch’s auto learning function will be disable except the specific port (set in the “Disable auto learning excluding uplink port” setting), and the Switch will 
forward data following the Static MAC Address Table to the specific port. Select “Disabled”, the Switch will learn and build MAC address table automatically 
and the Switch will forward data following the auto learning MAC Address Table to the specific port. 
 
Disable auto learning excluding uplink port: When enable the Static MAC function, the Switch’s auto learning function will be disable, check the dialog box of 
the “Disable auto learning excluding uplink port” and then check the dialog box of port numbers to enable the auto learning function of the port, and the 
Switch will forward data following the Static MAC Address Table and the Switch’s auto learn MAC address table to the specific port. 
 

Dynamic Forwarding Table

: Select the “Dynamic Forwarding Table” at Operation Tab, and select a port which you need to list all the MAC Address 

connected to this port, 
 

Содержание DES-1226G

Страница 1: ...D Link DES 1226G Web Smart 24 Port 10 100Mbps 2 Port Combo 10 100 1000Mbps Copper SFP Mini GBIC Gigabit Switch Manual Second Edition Building Networks for People RECYCLABLE...

Страница 2: ...8 Configuring Setup Setting 13 Port Settings 13 VLAN Settings Virtual Local Area Network 13 Trunk Setting 14 Mirror Setting 15 SNMP Setting 15 Configure SNMP Community 15 Configure SNMP Trap 16 Static...

Страница 3: ...ective way of increasing the total network capacity available to users on a LAN If an Ethernet network begins to display symptoms of congestion low throughput slow response times and high rates of col...

Страница 4: ...ional copper or fiber Gigabit connections Auto MDI MDI X support on each port Full half duplex transfer mode for 10 100Mbps Fast Ethernet transmission Full duplex transfer mode for Gigabit Ethernet tr...

Страница 5: ...a 10 100 1000Mbps Ethernet network Blinking When the LED is blinking the respective port is transferring or receiving data on a 10 100 1000Mbps Ethernet network Off No link 1000Mbps On When the LED l...

Страница 6: ...tiable 10 100 1000Mbps and also support auto MDI MDIX crossover detection These two ports can operate in half and full duplex modes SFP Mini GBIC Ports Option Port 25 26 The Switch is equipped with tw...

Страница 7: ...device The rubber feet cushion the Switch and protect the Switch case from scratching Figure 4 Attach the adhesive rubber pads to the bottom Rack Mounting The DES 1226G can be mounted in an EIA stand...

Страница 8: ...w the on screen instructions to install the utility 5 Upon completion go to Program Files web_management_utility and execute the Web Management utility Figure 1 Figure 7 Web Management Utility The Web...

Страница 9: ...he events that occur from the Web Smart Switch in the Monitor List There is a light indicator behind the View Trap button When the light is green it indicates that no trap has been transmitted and whe...

Страница 10: ...rocess the password change immediately Figure 11 Password Change Firmware Upgrade When the device has a new function there will be a new firmware to update the device You can use this function to upgr...

Страница 11: ...tual LAN Group setting VLAN Trunking Port Mirroring SNMP Static MAC QoS System Setting Device status Login Before you configure this device note that when the Web Smart Switch is configured through an...

Страница 12: ...lick on the setup item that you want to configure There are thirteen options Port Settings VLAN Settings Trunk Setting Mirror Setting SNMP Setting Static MAC QoS Setting Device Status Statistic System...

Страница 13: ...00M Full 100M Half 10M Full 10M Half Auto and Disable for speed or port disable selections Flow Control This setting determines whether or not the Switch will be handling flow control Set FlowCtrl to...

Страница 14: ...two or more devices with a larger bandwidths There are three Trunk groups to be set and there are default ports in each member Checked Enable to use the trunk function select the ports in each member...

Страница 15: ...over the network The Switch supports the SNMP versions 1 In SNMP v 1 user authentication is accomplished using community strings which function like passwords The remote user SNMP application and the...

Страница 16: ...ss Apply to save change of the SNMP Community Group Figure 196 Modify SNMP Community group Configure SNMP Trap Figure 27 Configure SNMP Trap Setting Trap authentication fail When checked the dialog bo...

Страница 17: ...MAC function on the Switch the Switch s auto learning function will be disable except the specific port set in the Disable auto learning excluding uplink port setting and the Switch will forward data...

Страница 18: ...Static MAC Setting Add Static MAC rule Press Add Mac button and the Static MAC Setting window will pop out fill in the specific MAC address select the specific port and Vid Press Apply to add rule to...

Страница 19: ...e Static MAC rule to forward the packets Figure 35 Add Delete Static MAC QoS Setting To set the Switch QoS base on IEEE 802 1p Figure36 802 1P based QoS Setting Device Status Click on the Status to pr...

Страница 20: ...s of the manager where the trap is to be sent Figure 39 Trap Setting System Events Monitoring the system s trap Device Bootup A trap when booting up the system Illegal Login A trap when an incorrect p...

Страница 21: ...file Figure 41 Backup Setting Note when restoring a recorded file the current password will not be erased Reset Setting The Factory Reset button helps you to reset the device back to the default setti...

Страница 22: ...recommended Fiber module SFP Mini GBIC Fiber module Number of Ports 24 10 100BASE TX Auto MDIX STP ports 2 1000BASE T Auto MDIX STP ports 2 SFP Mini GBIC fiber slot Physical and Environmental AC input...

Страница 23: ...ng sold As Is without any warranty whatsoever including without limitation the Limited Warranty as described herein notwithstanding anything stated herein to the contrary Submitting A Claim The custom...

Страница 24: ...pyright Statement No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to make any derivative such as translation transformation...

Страница 25: ...egistration Register online your D Link product at http support dlink com register Product registration is entirely voluntary and failure to complete or return this form will not diminish your warrant...

Страница 26: ...nek Aurum ul Walic w 11 PL 00 851 Warszawa Poland TEL 48 0 22 583 92 75 FAX 48 0 22 583 92 76 URL www dlink pl Hungary R k czi t 70 72 HU 1074 Budapest Hungary TEL 36 0 1 461 30 00 FAX 36 0 1 461 30 0...

Страница 27: ...site 1 employee 2 9 10 49 50 99 100 499 500 999 1000 or more 3 What network protocol s does your organization use XNS IPX TCP IP DECnet Others_____________________________ 4 What network operating sys...

Страница 28: ......

Отзывы: