background image

ENGLISH

16

Networking Basics

Check your IP address

After you install your new D-Link adapter or if you already have an Ethernet adapter installed on your computer, by default, the TCP/IP settings 

should be set to obtain an IP address from a DHCP server (i.e. router) automatically. To verify your IP address, please follow the steps below.

•  Click on 

Start

 > 

Run

. In the run box type 

cmd

 and click 

OK

. (Windows® 7 and Vista® users type 

cmd

 in the Start Search box.)

•  At the prompt, type 

ipconfig

 and press 

Enter

.

•  This will display the IP address, subnet mask, and the default gateway of your adapter.

Содержание DES-1008E

Страница 1: ......

Страница 2: ...y the United States Copyright Act of 1976 and any amendments thereto Contents are subject to change without prior notice Copyright 2010 by D Link Corporation D Link Systems Inc All rights reserved FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protecti...

Страница 3: ...el LEDs 10 Rear Panel Connections 11 Installation 12 Before You Connect to the Network 12 Mounting the Switch on the Wall 13 Mounting on a cement wall 13 Mounting on a wood wall 13 Connecting the Switch 14 PC to DES 1008E 14 Hub Switch to DES 1008E 14 DES 1008E to Other Devices 14 Port Speed Duplex Mode 14 Troubleshooting 15 Networking Basics 16 Check your IP address 16 Statically Assign an IP add...

Страница 4: ...rrectly when you follow the operating instructions Keep your system away from radiators and heat sources Also do not block cooling vents Do not spill food or liquids on your system components and never operate the product in a wet environment If the system gets wet see the appropriate section in your troubleshooting guide or contact your trained service provider Do not push any objects into the op...

Страница 5: ...e prong plugs to help ensure proper grounding Do not use adapter plugs or remove the grounding prong from a cable If you must use an extension cable use a 3 wire cable with properly grounded plugs Observe extension cable and power strip ratings Make sure that the total ampere rating of all products plugged into the extension cable or power strip does not exceed 80 percent of the ampere ratings lim...

Страница 6: ...ge ESD 1 When unpacking a static sensitive component from its shipping carton do not remove the component from the antistatic packing material until you are ready to install the component in your system Just before unwrapping the antistatic packaging be sure to discharge static electricity from your body 2 When transporting a sensitive component first place it in an antistatic container or packagi...

Страница 7: ...ive and high performance solution for small workgroups SMBs Small to Medium Businesses and any network supporting bandwidth intensive applications Fast Ethernet technology operates at 10 times the speed of traditional Ethernet offering maximum performance and enhanced capability for existing Ethernet based networks 100Mbps Fast Ethernet is a standard specified by the IEEE 802 3 LAN committee It is...

Страница 8: ...hubs beyond the two repeater limit A switch can be used to split parts of the network into different collision domains making it possible to expand your Ethernet network beyond the 205 meter network diameter limit for 100BASE TX networks Switches supporting both 10Mbps Ethernet and 100Mbps Fast Ethernet are also ideal for bridging between existing 10Mbps networks and newer 100Mbps networks Switchi...

Страница 9: ...date 10Mbps or 100Mbps devices providing a flexible solution for existing 10Mbps Ethernet workgroups The DES 1008E combines dynamic memory allocation with store and forward switching to ensure that the buffer is effectively allocated for each port and it controls the data flow between the transmit and receive nodes to guarantee against possible packet loss The DES 1008E is an unmanaged 10 100Mbps ...

Страница 10: ...ght is on when the DES 1008E is receiving power otherwise it is off Link Act This LED indicator light is green when the port is connected to an Ethernet device and will blink as Ethernet data is transmitted or received Hardware Overview Top Panel LEDs ...

Страница 11: ...g either a Crossover or Straight Through CAT5 cable into any port Power Jack Power is supplied through an external power adapter Check the technical specification section for information about the power input voltage Since the DES 1008E does not require a power button plugging its power adapter into a power outlet will immediately power it on Rear Panel Connections ...

Страница 12: ... cord and see that it is fully secured to the AC power port Make sure that there is adequate space for proper heat dissipation from and adequate ventilation around the Switch Leave at least 10 cm 4 inches of space at the front and rear of the Switch for ventilation Install the Switch in a fairly cool and dry place for the acceptable temperature and humidity operating ranges Install the Switch in a...

Страница 13: ... LEDs Please refer to the illustration below Mounting on a cement wall 1 Mount the Nylon screw anchors into a cement wall 2 Drive the T3 x 15L screws into the Nylon screw anchors 3 Hook the mounting holes of the switch back on the screws Mounting on a wood wall 1 Drive the T3 x 15 L screws into the wood wall 2 Hook the mounting holes of the switch back on the screws 1 3 4 inch minimum for wood wal...

Страница 14: ... 5 cable must be used The connection is accomplished from any port of the hub to any port of the DES 1008E DES 1008E to Other Devices The DES 1008E can be connected to another switch or other devices routers bridges etc via a two pair Category 3 4 5 UTP STP Straight Through or Crossover cable A Category 5 or higher cable must be used for 100Mbps operation The connection can be accomplished from an...

Страница 15: ...mputer 2 Does the DES 1008E switch have an uplink port The DES 1008E has Auto MDI ports which automatically sense the type of cable being used e g Crossover or Straight through and adjust themselves accordingly to pass data over the network 3 What is the maximum length of Category 3 4 or 5 twisted pair cable that can be used between the DES 1008E and other devices such as routers switches computer...

Страница 16: ...ttings should be set to obtain an IP address from a DHCP server i e router automatically To verify your IP address please follow the steps below Click on Start Run In the run box type cmd and click OK Windows 7 and Vista users type cmd in the Start Search box At the prompt type ipconfig and press Enter This will display the IP address subnet mask and the default gateway of your adapter ...

Страница 17: ...k on the Local Area Connection which represents your network adapter and select Properties Step 3 Highlight Internet Protocol TCP IP and click Properties Step 4 Click Use the following IP address and enter an IP address that is on the same subnet as your network or the LAN IP address on your router Example If the router s LAN IP address is 192 168 0 1 make your IP address 192 168 0 X where X is a ...

Страница 18: ...sTransfer Mode Aconnectionorientedtransmissionprotocolbasedon fixedlengthcells packets ATM isdesigned tocarryacomplete range of user traffic including voice data and video signals Auto Negotiation A feature on a port which allows it to advertise its capabilities for speed duplex and flow control When connected to an end station that also supports auto negotiation the link can self detect its optim...

Страница 19: ...rk bandwidth and can cause network failure Console Port The port on the Switch accepting a terminal or modem connector It changes the parallel arrangement of data within computers to the serial form used on data transmission links This port is most often used for dedicated local management CSMA CD Channel access method used by Ethernet and IEEE 802 3 standards in which devices transmit only after ...

Страница 20: ...o a network using TCP IP The address is written as four octets separated with full stops periods and is made up of a network section an optional subnet section and a host section IPX Internetwork Packet Exchange A protocol allowing communication in a NetWare network LAN Local Area Network A network of connected computing resources such as PCs printers servers covering a relatively small geographic...

Страница 21: ...can be configured so that one will take over data transmission should the other fail See also main port and standby port RJ 45 Standard 8 wire connectors for IEEE 802 3 10BASE T networks RMON Remote Monitoring Subset of SNMP MIB II which allows monitoring and management capabilities by addressing up to ten different groups of information RPS Redundant Power System A device that provides a backup s...

Страница 22: ...ocols providing Telnet terminal emulation FTP file transfer and other services for communication among a wide range of computer equipment Telnet ATCP IP application protocol that provides virtual terminal service letting a user log in to another computer system and access a host as if the user were connected directly to the host TFTP Trivial File Transfer Protocol Allows you to transfer files such...

Страница 23: ...ull duplex Fast Ethernet 100Mbps half duplex 200Mbps full duplex Topology Star Network Cables 10BASE T 2 pair UTP Cat 3 4 5 100 m EIA TIA 568 100 ohm STP 100 m 100BASE TX 2 pair UTP Cat 5 100 m EIA TIA 568 100 ohm STP 100 m Number of Ports 8 x 10 100Mbps auto negotiation auto MDI MDI X ports DC inputs DC 5V 1 2A Temperature Operating 0 50 C 32º to 122º F Storage 10 70 C 14ºto 158º F ...

Страница 24: ... x 38 1 mm 6 5 x 4 4 x 1 4 inch EMI FCC Class B CE Class B Security cUL CB Transmission Method Store and forward RAM Buffer 57Kbytes per device Filtering Address Table 2K entries per device Packet Filtering Forwarding Rate 10Mbps Ethernet 14 880 pps 100Mbps Fast Ethernet 148 800 pps MAC Address Learning Automatic update ...

Страница 25: ...ed on the label on the bottom of the switch e g rev A1 Serial Number s n number located on the label on the bottom of the switch You can find software updates and user documentation on the D Link website as well as frequently asked questions and answers to technical issues For customers within the United States Phone Support 877 453 5465 Internet Support http support dlink com For customers within...

Страница 26: ...ENGLISH 26 Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights Registration Version 1 1 May 18 2010 ...

Отзывы: