Usable window drives by D+H Mechatronic AG

Technical Data

Type 

 

GVL 8408-M-UL

Rated voltage

 

 

115 V AC ± 10%, 60 Hz

Rated power

 

 

388 VA

Stand-by operating 

ca. 2.5 W

Protection class 

 

I

Temperature range

 

-5 ... +40 °C (23...104°F)

Ingress protection

   

IP 30

Class of rating 

 

short-time duty, 20%

Output voltage 

 

24 V DC / residual ripple   10%

<

Safe output: *

Running current of drives 

6.4 A

Rated current of drives 

8 A

Housing 

 

plastic

colour of housing   

white

Housing dimensions

 

12.1'' x 12.1'' x 3.9''

   

 

310 x 310 x 100 mm

* Please observe:

The 

output current of the groups

 1 ... 5 amounts 

max. 4 A

.

The 

total output current

 of the control panel, is limited 

up to 8 A

.

Electrical devices, accessories and packaging should 
be sorted for environmental-friendly recycling.
Do not dispose electrical devices into household waste!

Disposal

To avoid accidents always disconnect the ventilation 
control from the power supply before cleaning or 
performing any maintenance.Inspection and 
maintenance has to be carried out according to 
D+H maintenance notes. Only original D+H spare 
parts may be used. Repair is to be carried out 
exclusively by D+H.
Wipe away debris or contamination with a dry, soft 
cloth.
Do not use cleaning agents or solvents.

Maintenance and cleaning

Mounting of drive:
Because  of  varied  possiblilties  for  choosing  drives, 
Please  take  mounting  informations  from  relevant 
instructions for use of the respective drive.

Moving direction of drives:
Change  poles  of  wires  of  the  drive  supply
(„Mot.a" and „Mot.b"), when moving direction is wrong.

Window drives (Accessories)

The control unit may only be operated with the following drives of which representative samples of the 
product series as specified on the respective certificate were tested according to the current UL 
requirements:

Series: VCD

Certificate Number 20150923-E222052

Models VCD 22/yyy, VCD 22/yyy-BSY, VCD 22/yyy-BSY+, MA 25 N-V2, VCD 204/yyy, VCD 203/yyy, and 
ZEL MA 25 G3/yyy.
Note: where yyy represents the stroke length up to 350 mm, MA 25 N-V2 UL with a stroke of 250 mm.

Series: CDC

Certificate Number 20170207-E222052

Models CDC-0252-0350-1-ACB, CDC-0252-0500-1-ACB, CDC-0252-0600-1-ACB, CDC-0252-0800-1-
ACB, CDC-0252-1000-1-ACB, CDC-TW-0502-0350-1-ACB, CDC-TW-0502-0500-1-ACB, CDC-TW-0502-
0600-1-ACB, CDC-TW-0502-0800-1-ACB, CDC-TW-0502-1000-1-ACB, may be followed by several digits 
refering to optional data signals and connections configurations.

Series: KA

Certificate Number 20150923-E222052

Models KA, followed by -TW or Blank, followed by 16, 34, 54, 66, or 106, followed by “/”, followed by yyyy, 
followed by Blank or -BSY+, may be followed by -SA, -SZ, -SGI or any alternate digits, where yyyy 
represents the stroke length in millimeters, from 0100 to a maximum of 1500

Series: CDP

Certificate Number 20150923-E222052 

Models CDP 800/yyyy-BSY+, CDP 1000/yyyy-BSY+, CDP 1500/yyyy-BSY+, CDP-TW 1600/yyyy-BSY+, 
CDP-TW 2000/yyyy-BSY+, CDP-TW 3000/yyyy-BSY+,, may be followed by several digits refering to 
optional data signals and connections configurations, with "yyyy" three of four digits for length of stroke 
from 600 to 1500 mm 

Series: LDx/VLD

Certificate Number 20160629-E222052

Models LDE or LDCO 1000/yyy, LDF 100/yyy, LDS 100/yyy, LDH 800/yyy, 
and linear drive for locking and unlocking motor-operated window models VLD 51/yyy-BSY+, VLD 51/yyy.
May be followed by various other suffixes.

Series: ZA/DXD-BSY

Certificate Number 20150923-E222052

Models ZA 35/yyyy-BSY+, ZA 85/yyyy-BSY+, ZA 105/yyyy-BSY+, ZA 155/yyyy-BSY+, may be followed by 
„-HS”, SXD 800/yyyy-BSY+, SXD 1000/yyyy-BSY+, SXD 1500/yyyy-BSY+; 
Double motor - Models DXD 150/yyyy-BSY+, DXD 300/yyyy-BSY+, may be followed by „-HS”, may be 
followed by various other suffixes. 
Louver operator drive - Models LA 35/yyyy-BSY+, LA 85/yyyy-BSY+, LA 105/yyyy-BSY+, LA 155/yyyy-
BSY+, may be followed by various other suffixes
Note: yyyy defines the stroke length in millimeters

Series: ZA-PLP

Certificate Number 20180207-E222052

Models ZA 35/yyyy, ZA 85/yyyy, ZA 105/yyyy, ZA 155/yyyy, ZA-0300-yyyy-1-PLP, ZA-0800-yyyy-1-PLP, 
ZA-1000-yyyy-1-PLP, ZA-1500-yyyy-1-PLP, 
Louver operator drive - Models LA 35/yyyy, LA 85/yyyy, LA 105/yyyy, LA 155/yyyy, LA-0300-yyyy-1-PLP, 
LA-0800-yyyy-1-PLP, LA-1000-yyyy-1-PLP, LA-1500-yyyy-1-PLP. May be followed by various other 
suffixes. May be followed by ,–HS”, may be followed by various other suffixes.
Note: yyyy defines the stroke length in millimeters.

Содержание GVL 8408-M-UL

Страница 1: ...GVL 8408 M UL en Original instructions Page 2 99 828 04 1 0 06 19...

Страница 2: ...al mechanical and flammability ratings or c Cable that is a factory connected integral part of a Class 2 power supply complying with the Standard for Class 2 Power Units referenced in Annex A Ref No 1...

Страница 3: ...y more separately from your D H distributor Further connecting plans are available there as well Performance features Ventilation safety function key operation OPEN CLOSE can be free encoded Weather a...

Страница 4: ...switch S5 group 1 5 22 12 AWG max 4 5 lb in Encoding of group DIP switches S1 S5 Following functions can be adjusted for each group separately with DIP switches S1 S5 on motherboard of control panel a...

Страница 5: ...3 5 112 180 299 4 98 164 262 ft ft ft type 2x AWG 16 2x AWG 14 2x AWG 12 total current 0 5 240 400 640 1 120 200 320 1 5 80 130 213 2 60 100 160 2 5 48 80 128 3 40 65 107 3 5 34 55 91 4 30 50 80 m m...

Страница 6: ...GVL 8408 M UL 99 828 04 1 0 06 19 6 12 English Connection 115 VAC supply cable tie for strain relief L N PE 115 V AC 60 Hz GVL 8408 M UL...

Страница 7: ...T 84 U SD L P Mot b Mot a 24 V DC Window Drives Mot b Mot a G Az Zz External contact for central closing e g rain detector X Line lengths and cross sections see page 5 The input current of the connect...

Страница 8: ...al only LT 84 U SD Vent buttons e g LT 84 U W LT 84 U SD L P Mot b Mot a 24 V DC Window Drives Mot b Mot a G Az Zz GVL 8408 M UL X Line lengths and cross sections see page 5 optional rain Wind 1 2 4 3...

Страница 9: ...the system will automatically close in case of wind or rain The system will not automatically open again if wind or rain has stopped Opening of the system for ventilation via vent button The weather a...

Страница 10: ...d packaging should be sorted for environmental friendly recycling Do not dispose electrical devices into household waste Disposal To avoid accidents always disconnect the ventilation control from the...

Страница 11: ...yyyy BSY CDP 1500 yyyy BSY CDP TW 1600 yyyy BSY CDP TW 2000 yyyy BSY CDP TW 3000 yyyy BSY may be followed by several digits refering to optional data signals and connections configurations with yyyy t...

Страница 12: ...Germany 22949Ammersbek 49 239 Tel 40 605 65 49 Fax 40 605 65 254 E Mail info dh partner com www dh partner com 2018 D H Mechatronic AG Ammersbek Technische nderungen vorbehalten Rights to technical mo...

Отзывы: