D-D The Aquarium Solution DUAL HEATING & COOLING CONTROLLER Скачать руководство пользователя страница 4

DU
AL
 

HEA

TING & COOLING 

CONTROLLER

 

   

 

www

.theaquariumsolution.

com

 

4

PRODUCT DESCRIPTION

The Dual Heaing & Cooling Controller is designed to allow precise 
control of the temperature in a marine aquarium.

The controller has 2 components:

1.

 

Double mains power socket – one power socket for heater control and 

the other for fan/chiller control.

2. 

Display with temperature sensor – used to set and display temperature 

and alarms and measure temperature. The plastic coated temperature 
sensor is waterproof and suitable for use in a marine aquarium.

Heaters of any type can be connected to the heating power socket 
(socket marked with a “ ” symbol). The maximum rating is 1,600W.

The cooling power socket is provided for controlling fans or coolers, 
(socket marked with a “ ” symbol). The maximum rating is 1,600 Watt, 
however, due to the high starting current of inductive loads such as a 
chiller, the maximum power rating for these devices is 600W maximum.

INSTALLATION

• 

   

Position the temperature sensor in the aquarium so that the probe end 
is completely submersed at all times in the aquarium water. Position this 
sensor probe in an area that is well away from any heater or chiller water 
return (failure to observe this can result in inaccurate temperature control).

• 

 

Connect a heater to the heater power socket (if the heater has a  
built-in thermostat, be sure to set the thermostat temperature higher 
than the aquarium temperature to prevent the thermostat from disabling  
the heater).

• 

 

Connect a fan/chiller to the cooling power socket (if the chiller/fan has  
a thermostat, be sure to set the thermostat temperature lower than  
the aquarium temperature to prevent the thermostat from disabling  
the chiller).

• 

Connect temperature controller to power and switch on

.

Содержание DUAL HEATING & COOLING CONTROLLER

Страница 1: ...P R O D U C T I N S T R U C T I O N M A N U A L DUAL HEATING COOLING CONTROLLER...

Страница 2: ...H E AT I N G C O O L I N G C O N T R O L L E R www theaquariumsolution com 2 1 2 3 5 4 1 Heating Socket 2 Cooling Socket 3 Arrow Keys for parameter adjustment 4 Status Indicators 5 Set Key to confirm...

Страница 3: ...oint temperature Display Resolution 0 1 C Accuracy 1 C Power supply 220VAC 15 50 60HZ Temp Sensor 1 x 2 metre NTC sensor Heating Control resistive load such as heater max 1600W Cooling Control inducti...

Страница 4: ...ol The maximum rating is 1 600 Watt however due to the high starting current of inductive loads such as a chiller the maximum power rating for these devices is 600W maximum INSTALLATION Position the t...

Страница 5: ...ed heater is switched on OFF Heating the heating power socket has no power applied heater is switched off ON Alarm the measured temperature is above the range set in the alarm setting also an audible...

Страница 6: ...ress the SET button once to advance to alarm differential setting 4 Alarm Differential can be adjusted to the target value by pressing the up down arrows range 0 5 to 5 0 C When the desired value is d...

Страница 7: ...eep flashing until the sensor temperature is within the range 24 3 to 25 7 C WARRANTY Should any defect in material or workmanship be found within 12 months of the date of purchase D D The Aquarium So...

Страница 8: ...R H E I Z U N D K H L R E G L E R www theaquariumsolution com 1 2 3 5 4 1 Heizsteckdose 2 K hlsteckdose 3 Pfeiltasten zur Einstellung der Parameter 4 Status Anzeige 5 Set Taste zur Best tigung der Ein...

Страница 9: ...omzufuhr 220 V Wechselstrom 15 50 60 Hz Temperatursensor 1 x 2 m NTC Sensor Heizregelung ohmsche Last beispielsweise Heizer max 1600 W K hlregelung induktive Last beispielsweise K hlger t max 600 W Be...

Страница 10: ...einem K hlger t liegt die maximale Nennleistung dieser Ger te allerdings bei maximal 600 W INSTALLATION Positionieren Sie den Temperatursensor so im Aquarium dass sich das Sensorende jederzeit vollst...

Страница 11: ...eingeschaltet OFF Heizen die Heizsteckdose f hrt keinen Strom Heizer ist ausgeschaltet ON Alarm die gemessene Temperatur ist oberhalb des in den Alarm Einstellungen festgelegten Bereichs es ert nt au...

Страница 12: ...3 und 16 0 C Wenn der gew nschte Wert im Display angezeigt wird dr cken Sie die SET Taste einmal um zur Alarmdifferenzeinstellung zu gelangen 4 Alarmdifferenz kann ber die Pfeiltasten Pfeil nach oben...

Страница 13: ...estellt werden aber der visuelle Alarm Alarm Icon wird weiterhin blinken bis die gemessene Temperatur im Bereich von 24 3 C bis 25 7 C liegt GARANTIE Sollte innerhalb von 24 Monaten nach dem Kauf ein...

Страница 14: ...F O N C T I O N C H AU F FAG E E T R E F R O I D I S S E M E N T www theaquariumsolution com 1 2 3 5 4 1 Prise Chauffage 2 Prise Refroidissement 3 Touches de r glage fl ch es 4 Indicateurs d tat 5 To...

Страница 15: ...solution d affichage 0 1 C Pr cision 1 C Alimentation lectrique 220 V CA 15 50 60 HZ Capteur de temp rature 1 x capteur CTN 2 m tres Contr le du chauffage charge r sistive de type l ment chauffant 1 6...

Страница 16: ...ermet de contr ler un ventilateur ou un refroidisseur Elle correspond une puissance maximale de 1 600 W Cependant en raison du courant de d marrage lev des charges inductives telles que les refroidiss...

Страница 17: ...chauffage est allum TEINT Chauffage la prise Chauffage est hors tension le dispositif de chauffage est teint ALLUM Alarme la temp rature relev e est situ e en dehors de la plage d finie pour l alarme...

Страница 18: ...ctionnez la valeur souhait e en appuyant sur les fl ches haut bas plage disponible 0 3 16 C Lorsque la valeur souhait e est affich e appuyez une fois sur la touche SET pour passer au r glage de la dif...

Страница 19: ...ter et une alarme sonore se d clenche Appuyez sur n importe quelle touche pour d sactiver l alarme sonore L alarme visuelle ic ne d alarme continuera clignoter jusqu ce que la temp rature relev e par...

Страница 20: ......

Отзывы: