10
16 V AC
220 V AC( from mains supply)
ELECTRICAL WIRING (S
& CONDO )
·
The transformer
must
be
plugged into
a
normal plug socket
in the house.
16
Volts AC
is
then run
directly to
the PC
board 16V
AC connection. The
distance
between the transformer
and the
motor
should not exceed 50 meters.
·
The cable should be run in a
3
00 mm deep trench in a water proof conduit and must be terminated
inside the motor.
·
There must be no joins in the cable underground.
·
The cable should be a
two
core 1.5mm cable.
DO
NOT USE COMMUNICATION CABLE
AS THIS
WILL VOID ANY WARRANTY AND IS ILLEGAL.
NOTE: the transformer must not be opened in any way as this may cause electrical shock
Connect from the transformer 16Volts AC to the
16v AC
on the main PC board.
WIRING DIAGRAM FROM TRANSFORMER TO CHARGER (S
& CONDO)
The following section explains how the wiring should be done for the CONDO and S
motors
only.