19
EN / CZone® Control X User & Installation Manual
SET DIPSWITCH
1. With a screwdriver, remove the dipswitch cover from the Control X.
2. Using a small screwdriver, carefully set the dipswitch to the required setting. The dipswitch number must be
unique for all modules on the CZone network and must match the dipswitch setting in the configuration to
function correctly.
3. Replace dipswitch cover once correct dipswitch setting has been configured, ensuring not to overtighten screws.
NOTE
– Control X is only Ingress Protected and Ignition Protected when dipswitch cover is fitted correctly.
The example shows a dipswitch number of 10000000 where 0 = Off and 1 = On.
Figure 11. Setting Dipswitch
INITIAL POWER UP
1. Check all plugs are securely seated and power connections are tight.
2. Check dipswitch setting of Control X to match with new configuration.
3. Turn the switch/circuit breaker on supplying the Control X’s main positive stud.
4. Check that the Power indicator LED is green.
5. Power up the NMEA2000 network.
6. Check that the NMEA2000 Network LED lights up. It may also be flashing if other devices are present and
transmitting data.
7. Check the circuit’s status LEDs for each individual circuit. Refer to LED codes to diagnose any faults which
need to be rectified.
8. Check the software version of all modules on the network, including the Control X, with the CZone Configuration
Tool and update if necessary.
9. Write configuration file to the Control X and the rest of the CZone modules on the system (Refer to the CZone
Configuration Tool Instructions for details on how to configure the Control X).
10. Test all inputs and outputs for configured functionality.