background image

 

Control X

 

User & Installation Manual 

V1.0 

 
 

 

Содержание Control X

Страница 1: ...Control X User Installation Manual V1 0...

Страница 2: ...ations of either its products or associated documentation Translations In the event that there is a difference between a translation of this manual and the English version the English version should b...

Страница 3: ...stallation Precautions 6 3 OVERVIEW 7 Description 7 Features 7 Control X Overview 8 LED Indicators 9 Capacitive Touch Panel 10 System Example 11 4 INSTALLATION 12 Things You Need 12 Environment 12 Mou...

Страница 4: ...nting Screw Locations 13 Figure 7 Control X PLUS Channel Specifications 14 Figure 8 Control X Channel Speifications 15 Figure 9 Control X Connections 16 Figure 10 Control X Main Supply Wiring 18 Figur...

Страница 5: ...ocally applicable standards and taking into consideration the safety guidelines and measures chapter 2 of this manual Please keep this manual in a secure place GUARANTEE SPECIFICATIONS BEP Marine guar...

Страница 6: ...instructions in the installation manual 3 Use of the Control X other than mentioned in point 2 is not considered to be consistent with the intended purpose BEP Marine is not liable for any damage resu...

Страница 7: ...ease of installation on wide range of boats and RV s where space is limited IPX7 enclosure allows for installation in all environments 100 solid state switching provides improved reliability silent op...

Страница 8: ...l X and Control X PLUS specs 2 Circuit Label 3 Main Supply Terminal Panel 4 Dipswitch Cover 5 Connector A DTP06 4S 6 Connector B DT06 12SA 7 Connector C DT06 12SB 8 NMEA2000 Micro C Connector 9 Capaci...

Страница 9: ...ured 2 Red Flash Configuration Conflict 3 Red Flash DIP Switch Conflict 5 Red Flash No Modules Detected 7 Red Flash Over Current 9 Red Flash Missing Commander 2 Power LED Colour Description Off Power...

Страница 10: ...equired for operation of the touch pad buttons NOTE A Control X with any circuit forced ON via manual override will not be able to be put to sleep until the circuit has been reset This is designed as...

Страница 11: ...WATER TANK SENDER RGBW ZONE 1 RED RGBW ZONE 1 GREEN RGBW ZONE 1 WHITE RGBW ZONE 1 BLUE SHUNT INPUT BATTERY SHUNT INPUT LOAD SALOON LIGHT SWITCH TO NEG CABIN LIGHT SWITCH TO NEG 24HR BILGE PUMP FLOAT S...

Страница 12: ...e following stipulations during installation Ensure the Control X is located in an easily accessible location for quick access to module Ensure indicator LEDs are visible for troubleshooting Ensure ci...

Страница 13: ...own in Figure 7 and Figure 8 Assign each input and output to a channel on the Control X ensuring loads are wired to the appropriate channel for the functionality required All high side output channels...

Страница 14: ...B6 10A B7 10A B8 10A B9 10A B10 10A B11 10A B12 10A 8x 5A Low Side Outputs or 10x Full SI Inputs Shunt Input 30A Connector Max C1 Shunt Input C2 Full SI Only Ignition Wake C3 5A RGBW Z2 Red C4 5A RGB...

Страница 15: ...10A B4 10A B5 10A B6 10A B7 10A B8 10A B9 10A B10 10A B11 10A B12 10A 4x 5A Low Side Outputs or 10x Full SI Inputs Shunt Input 20A Connector Max C1 Shunt Input C2 Full SI Only Ignition Wake C3 Full SI...

Страница 16: ...be plugged with sealing plugs to maintain the IPX7 rating Deutsch part 114017 ZZ 4 Before inserting the connector it s highly recommended to apply a small amount of silicone grease along the sealing s...

Страница 17: ...the function required Referring to the circuit list strip and crimp the input output cables with the appropriate Deutsch contact and crimp tool NOTE Pins 1 and 12 are dedicated shunt input pins only...

Страница 18: ...X 4 Ensure supplied spring washer is installed and M8 nut is torqued to 10Nm max 6 Connect DC Positive 1 Connect an appropriately sized and fused cable from the battery positive terminal to the Contro...

Страница 19: ...ly seated and power connections are tight 2 Check dipswitch setting of Control X to match with new configuration 3 Turn the switch circuit breaker on supplying the Control X s main positive stud 4 Che...

Страница 20: ...on the Control X PLUS allowing reversing motors to be connected directly to the module The channels are available on Plug A A combination of 1x H Bridge output and 2x single channel outputs or 2x H B...

Страница 21: ...tomatic float switches or CZone can trigger system alarms to notify owners of automatic bilge pump operation and optionally use this run signal to turn on other circuits like additional pumps You can...

Страница 22: ...and unlike other multiplex switching modules multiple switches can be pressed at the same time GND for the CZone MUX must return to the same module the Resistor Module is connected to The total wire...

Страница 23: ...he synchronization of multiple wipers Wiper motors connected to the H Bridge channel outputs also have the optional setting of braking the wiper motor to assist with accurate parking of the wiper arms...

Страница 24: ...tness level and lighting effects Additionally you can independently dim each light circuit on the same zone allowing complete control of the system High side dimming will allow dimming of each light c...

Страница 25: ...ONNECTORS 80 911 0231 01 CZONE CONTROL X INTERFACE ONLY 80 911 0232 00 CZONE CONTROL X PLUS CONNECTOR KIT 80 911 0233 00 CZONE CONTROL X CONNECTOR KIT CZONE MUX PARTS Part Number Description Quantitie...

Страница 26: ...ng All Output Channels Bilge Pump Running Detection All High Side Output Channels Addition Inputs Shunt State Of Charge Multiplex Switch Inputs Power supply M6 1 4 Positive Terminal 9 32V Network Supp...

Страница 27: ...27 EN CZone Control X User Installation Manual DIMENSIONS Figure 17 CZone Control X Dimensions...

Страница 28: ...EN CZone Control X User Installation Manual 28 11 COMPLIANCE...

Страница 29: ...29 EN CZone Control X User Installation Manual...

Отзывы: