Cyrus DAC X Signature Скачать руководство пользователя страница 9

Cyrus DAC X Signature

User Instructions

7

seTTINg uP (dAc X sIgNATuRe)

There are many configuration options available in the setup menu to customise 
the DAC X Signature to best match each individual system.

To enter the menu system, press the front panel SETUP key 

f

. Turn the 

Rotary control 

e

 to scroll through the options available on the display. 

Press  the  Rotary  control 

e

  to  select  the  option  displayed.  During  the 

setup sequence, you can move to the next or previous step by pressing 
the Input up or down buttons.
Press  the  SETUP 

f

  key  to  exit  setup  and  save  any  changed  settings. 

Note that the setup sequence will exit, saving any changed settings after 
10 seconds of inactivity or after the last option ‘Name input 6’ has been 
completed.

 The setup menu options are shown here –

Input display

Small Input Names

Display Mode

There are two modes of display operation. The small setting will show 
a two-line display with the selected input in the display centre and the 
current sample rate/lock status at the bottom. The large setting will show 
a single line display with a larger input legend. 

Input names

Input name

Input 1

DVD

<

>

When the DAC X Signature leaves the factory, the input names are set to 
correspond to the rear panel connections, for example Input 1 will display 
as Input 1.
The name of any input may be changed to a choice from the following 
list-

No source (off)

• 

LaserDisc, DVD, DVD 2, DVD-A, CD, CD 2

• 

Linkserver, Linkport

• 

Jukebox, Phono

• 

Tuner, DAB, TV, AV, Cyrus AV, Satellite, Satellite 2, Cable

• 

Video, VCR, VCR 2, Tape, MiniDisc, DAT

• 

PC, Games, Keyboard, Aux, AV Direct, Stream X

• 

To change the names of the inputs, we recommend making a list of each 
input number with your preferred name from the choices above before 
setting the names. 
No source is a special function name, used to name inputs that have no 
source connected to them. These input numbers will not then appear in 
the input selector sequence.

Restoring factory settings

You can also restore all configuration options to the initial default settings 
that were applied at the factory.
NOTE: This operation is not reversible. 
To restore factory settings, disconnect mains power from the unit. Now 
re-connect mains power while holding down the Standby key.

Digital filter
Display options
Connected to:
Name Input 1

Choose a name for input 1 from the name list

Choose a name for input 2 from the name list

Choose a name for input 3 from the name list
Choose a name for input 4 from the name list
Choose a name for input 5 from the name list

Choose a name for input 6 from the name list

Name Input 2

Name Input 3
Name Input 4
Name Input 5

Name Input 6
Storing settings

Save settings and exit setup

Phase adjust

Select normal or inverted
Select fast or slow roll off
Select large or small
Select CD, TU, AU or AV

Setup

Phase adjust

Normal

Phase

This menu option sets the audio phase for the DAC. The factory setting is 
normal. Some listeners may prefer the inverted setting with their systems 
or for when playing particular recordings.

digital filter Response

Fast Roll-off

Digital Filter Response

This menu option gives two settings for the digital filtering of the DAC 
stage.  Choose  your  preference  of  Fast  or  Slow  roll-off  by  auditioning 
some of your favourite tracks with each setting.

dAcX connected to:

This  option  may  be  used  to  change  the  remote  control  and  MC-BUS 
response of the DAC X Signature. From the factory, the DAC X Signature 
will power on in response to a CD select command from a Cyrus remote 
control  or  from  a  CD  select  signal  sent  via  MC-BUS,  so  if  the  DAC  X 
Signature is connected to the CD input of the amplifier, no change will 
be required to this setting. If, however, the DAC X Signature is connected 
to the TU, AU or AV inputs of the amplifier, the appropriate remote and 
MC-BUS responses may be selected through this menu option to ensure 
power-on compatibility with the amplifier.

Содержание DAC X Signature

Страница 1: ...ENGINEERED TO ENTERTAIN...

Страница 2: ...ting Power amplifiers 9 Connecting to power amplifiers with phono inputs 9 Connecting to power amplifiers with balanced inputs 9 Fixed output 9 Connecting a Cyrus Surround Sound decoder 9 Connecting a...

Страница 3: ...urges BATTERIES Warning Batteries shall not be exposed to excessive heat such as sunshine fire or the like CAUTION POLARISED CONNECTOR CANADA and USA To prevent electrical shock match wide blade of pl...

Страница 4: ...igh temperature dust or humidity Never stand the DAC under another unit or on any surface likely to hamper its cooling or ventilation IMPORTANT NOTE To avoid damage to your system always ensure that m...

Страница 5: ...BALANCED OUT L L L PRE OUT 1 IN 8 PRE OUT 2 IN 7 FIXED MADE IN ENGLAND 230V 50 60Hz 25W OUT IN MC BUS IN 3 IN 2 IN 1 IN 4 OUT 1 IN 6 IN 5 a b c d e f 1 1 ghi1 Input 3 Digital 7 Input 4 Digital 8 Inpu...

Страница 6: ...as a multi channel surround decoder or a digital tape disc recorder The currently selected digital input signal will be routed to this output External Regulated Power Supply PSX R The PSX R is a uniq...

Страница 7: ...User Instructions 5 OPERATION DAC X Signature Key to the front panel drawing Standby key 1 Standby light 2 Display window 3 Setup adjust 4 Setup select 5 Input select 6 CD Sample rate 44 1kHz SETUP IN...

Страница 8: ...ns available from the setup menu The factory default small input display option will also identify the sample rate of the selected source and indicate Invalid Audio Format for program material which t...

Страница 9: ...ese input numbers will not then appear in the input selector sequence Restoring factory settings You can also restore all configuration options to the initial default settings that were applied at the...

Страница 10: ...nections 3 Optical digital output 4 Input 1 Optical 5 Input 2 Optical 6 Input 3 Digital 7 Input 4 Digital 8 R R R USE PSX R ONLY BALANCED OUT L L L PRE OUT 1 IN 8 PRE OUT 2 IN 7 FIXED MADE IN ENGLAND...

Страница 11: ...DAC stage of the DAC XP Signature and bypasses the internal preamplifier and volume control It may be used to feed the DAC stage output to an external system preamplifier or for high quality tape rec...

Страница 12: ...he power function of all connected Cyrus components may be controlled from the DAC XP Signature front panel or remote control Refer to the following table for Cyrus components that will be activated b...

Страница 13: ...nature Standby key 1 Standby light 2 Remote eye 3 Display window 4 Level control and setup adjust 5 Key to the front panel drawing Setup select 6 Channel balance select 7 Mute 8 Input select 9 27 CD S...

Страница 14: ...n normal mode the level control sets the volume in 1dB steps A bargraph and a numeric scale at the top of the display window show the current volume setting The last used volume setting is stored when...

Страница 15: ...DE INFO TEXT TV AV CONTROL SOURCE Switching on Cyrus components Press one of the keys in the SOURCE group 1 2 3 4 5 7 9 6 8 0 10 SAT TV STORE MENU ENTER SELECT LIST CH SETUP abc def ghi jkl mno pqrs t...

Страница 16: ...command for an amplifier 14 No command for an amplifier 15 No command for an amplifier 16 No command for an amplifier 17 No command for an amplifier 18 No command for an amplifier 19 No command for a...

Страница 17: ...is changed the display text area will show the message Phase Normal or Phase Invert The performance of the CD player is unaffected whether the signal is in normal or phase inverted mode CD player stop...

Страница 18: ...and for an audio streamer 12 Amplifier mute 13 No command for an audio streamer 14 No command for an audio streamer 15 No command for an audio streamer 16 Audio streamer stop 17 No command for an audi...

Страница 19: ...learn for example volume up until the mode key flashes red This indicates that the command has been received Release the key on the reference remote control 6 Press a key on the Cyrus remote control...

Страница 20: ...sitivity for input 7 Set the sensitivity for input 8 Name Input 2 Name Input 3 Name Input 4 Name Input 5 Name Input 6 Name Input 7 Name Input 8 Trim Input 7 Trim input 8 Storing settings Save settings...

Страница 21: ...output channels from the DAC XP Signature Switch off the power to the audio system before making any changes to the connections Remote control not operating Remote control not operating lights on remo...

Страница 22: ...t transferable Please retain the sales receipt as proof of purchase Warranty claims must wherever possible be made through the retailer from whom the equipment was purchased This warranty excludes Dam...

Страница 23: ...Cyrus Audio Ltd Ermine Business Park Huntingdon PE29 6XY U K...

Отзывы: