3. Field Installation Checklist
☐
The Central unit and access control panel need a common ground.
☐
The Remote unit and card reader need a common ground.
☐
The top of each unit (where antennas are located) should point toward the sky.
☐
The Central and Remote units should be installed level relative to each other.
☐
There should be a direct line of sight between Central and Remote units (if there is no direct line of sight,
a Repeater unit is recommended).
☐
Both the Central and Remote units should be mounted high enough to avoid interference from obstacles
(vehicles, trains, buildings, trees, etc.).
☐
Metal mounting surfaces are not recommended. If use of a metal surface is unavoidable, space unit as far
from metal surface as possible using non-metal spacer.
☐
Enclosure locking screws (6-32 x 3/8) max torque rating 8.5 inch-pounds.
If troubleshooting is necessary, see manual.
Typical Suprex® RF Central and Remote Wiring Connections
Ground
LED Out
Data1
Data 0
N.O.
COM
Access
Control
Panel
+8 to +16 VDC
Ground
LED In
Data 1
Data 0
R1 IN
Ground
SPX-56
31 / 5641
Central
DC Power
Supply
Power
Ground
+8 to +16 VDC
Ground
LED OUT
Data 1
Data 0
R1 N.O.
R1 COM
R1 N.C.
Card
Reader
Power
Ground
LED IN
Data 1
Data 0
Door
Strike
Output
SPX-56
31 / 5641
Remote
Typical S
Series
Central and Remote Connections
DC Power
Supply
Power
Ground
10/26/2020 Complete documentation PDFs at CypressIntegration.com
Ground
LED Out
Data1
Data 0
N.O.
COM
Access
Control
Panel
+8 to +16 VDC
Ground
LED In
Data 1
Data 0
R1 IN
Ground
SPX-56
31 / 5641
Central
DC Power
Supply
Power
Ground
+8 to +16 VDC
Ground
LED OUT
Data 1
Data 0
R1 N.O.
R1 COM
R1 N.C.
Card
Reader
Power
Ground
LED IN
Data 1
Data 0
Door
Strike
Output
SPX-56
31 / 5641
Remote
Typical S
Series
Central and Remote Connections
DC Power
Supply
Power
Ground