Suprex Operation and Initial Setup
Actual connections will differ based on the type of format, features utilized, and equipment interface.
"
The following diagrams are an example of a typical installation using the Suprex 1300 and a Wiegand format
Reader and Access Control Panel.
"
"
1. First connect units as shown below to verify basic function and communication. This should be done in a
convenient location such as a bench top before installing units in the field. Both units can share the same power
supply if the power supply has sufficient capacity.
"
""
When Connected as shown below, both units should have the Diagnostic LED flashing Green about 2-3 flashes
per second (Rapid flashing)
Central Unit
*
Remote Unit
2-8 to 16 VDC In
"
1-Ground
12-RLY2 N.O.
"
11-RLY2 Com
"
10-RLY2 N.C.
"
9-RLY1 N.O.
"
8-RLY1 Com
"
7-RLY1 N.C.
"
6-RS232 Out
"
5-RS232 In
"
4-Ground
"
3-Aux In
"
2-N/C
"
1-N/C
"
8-485(+)
"
7-485(-)
"
6-+5 VDC Out
"
5-RLY4 Input (5V)
"
4-RLY3 Input (5V)
"
3-LED Output
"
2-D1/Data/F2F Input
"
1-D0/CLK Input
2-8 to 16 VDC In
"
1-Ground
8-485(+)
"
7-485(-)
"
6-+5 VDC Out
"
5-Prog Res 2
"
4-Prog Res 1
"
3-LED Input
"
2-D1/Data/F2F Out
"
1-D0/Clock Out
"
1-D0/CLK Output
12-RLY4 N.O.
"
11-RLY4 Com
"
10-RLY4 N.C.
"
9-RLY3 N.O.
"
8-RLY3 Com
"
7-RLY3 N.C.
"
6-RS232 Out
"
5-RS232 In
"
4-Ground
"
3-Aux Out
"
2-Relay2 Input
"
1-Relay1 Input
"
8 - 16 VDC
"
Power
"
Supply
Ground (0V)
+VDC
8 - 16 VDC
"
Power
"
Supply
Ground (0V)
+VDC