background image

*

*

Remote Unit

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

Suprex Operation and Initial Setup

I/O Controls

Central Unit

2-8 to 16 VDC In

"

1-Ground

8-485(+)

"

7-485(-)

"

6-+5 VDC Out

"

5-Prog Res 2

"

4-Prog Res 1

"

3-LED Input

"

2-D1/Data/F2F Out 

"

1-D0/Clock Out

"

1-D0/CLK Output

12-RLY4 N.O.

"

11-RLY4 Com

"

10-RLY4 N.C.

"

9-RLY3 N.O.

"

8-RLY3 Com

"

7-RLY3 N.C.

"

6-RS232 Out

"

5-RS232 In

"

4-Ground

"

3-Aux Out

"

2-Relay2 Input

"

1-Relay1 Input

"

2-8 to 16 VDC In

"

1-Ground

12-RLY2 N.O.

"

11-RLY2 Com

"

10-RLY2 N.C.

"

9-RLY1 N.O.

"

8-RLY1 Com

"

7-RLY1 N.C.

"

6-RS232 Out

"

5-RS232 In

"

4-Ground

"

3-Aux In

"

2-N/C

"

1-N/C

"

8-485(+)

"

7-485(-)

"

6-+5 VDC Out

"

5-RLY4 Input (5V)

"

4-RLY3 Input (5V)

"

3-LED  Output

"

2-D1/Data/F2F Input

"

1-D0/CLK Input

Input

Red arrow denotes direction

!

of command signal

Output

LED Input and Output

6. The Cypress SPX-1300 provides additional data channels to support access control hardware such as door 
strikes, tamper alarms, request to exit status, etc.  These signals are sent to and from the Remote and Central units 
without the need to run additional wiring.

"

"

The accessory control I/O use active low inputs.  When the inputs are floating (nothing connected) the associated 
output will be set to a high level.  When the input is set to 0Volts (Ground) the input will activate its associated 
output.  All Accessory outputs are Open Collector type and will switch to Ground when activated.

"

"

Each input will have an associated output.  See the following pages for a diagram of each I/O pair.

"

Inputs can be tested by making a jumper connection to ground and monitoring the associated output. 

Содержание Suprex SPX-1300

Страница 1: ...Operations Manual Suprex Reader Extender SPX 1300 5 3 5 0 40 65 0 4 CYPRESS...

Страница 2: ...See Notes on following page for temperature and power ratings 3 3 DataBender CVX 1300 2 8 1 4 3 65 0 15 External Dimensions and Mounting Holes Unit Height 0 75 This complies with part 15 of the FCC ru...

Страница 3: ...F 2F connections support unsupervised mode only 1 2 3 4 5 6 7 8 Switch 6 7 8 0 1 x 2 x 3 x x 4 x 5 x x 6 x x 7 x x x Wiegand Wiegand No Filter Strobed Rising Edge MR 5 Strobed Rising Edge Dorad0 644 S...

Страница 4: ...llups on 0 24 VDC with pullups off All Digital Inputs and Outputs are 0 24 VDC tolerant Pullup resistors should be disabled when using I O at voltages greater than 5VDC to prevent excessive current dr...

Страница 5: ...s then the unit is not getting power The Diagnostic LED s will be illuminated when power is applied CENTRAL UNIT FLASHING BETWEEN RED GREEN With power applied and no communication path between the Rem...

Страница 6: ...onnected as shown below both units should have the Diagnostic LED flashing Green about 2 3 flashes per second Rapid flashing Central Unit Remote Unit 2 8 to 16 VDC In 1 Ground 12 RLY2 N O 11 RLY2 Com...

Страница 7: ...ction and operation is covered in the next 2 pages 8 16 VDC Power Supply DC Power In Ground LED In Data 1 Data 0 Wiegand Card Reader Remote Unit 2 8 to 16 VDC In 1 Ground 12 RLY2 N O 11 RLY2 Com 10 RL...

Страница 8: ...ta 0 Wiegand Access Control Central Unit 2 8 to 16 VDC In 1 Ground 8 485 7 485 6 5 VDC Out 5 Prog Res 2 4 Prog Res 1 3 LED Input 2 D1 Data F2F Out 1 D0 Clock Out 1 D0 CLK Output 12 RLY4 N O 11 RLY4 Co...

Страница 9: ...LED Input 2 D1 Data F2F Out 1 D0 Clock Out 1 D0 CLK Output 12 RLY4 N O 11 RLY4 Com 10 RLY4 N C 9 RLY3 N O 8 RLY3 Com 7 RLY3 N C 6 RS232 Out 5 RS232 In 4 Ground 3 Aux Out 2 Relay2 Input 1 Relay1 Input...

Страница 10: ...direction of command signal Output LED Input and Output 6 The Cypress SPX 1300 provides additional data channels to support access control hardware such as door strikes tamper alarms request to exit s...

Страница 11: ...O 8 RLY3 Com 7 RLY3 N C 6 RS232 Out 5 RS232 In 4 Ground 3 Aux Out 2 Relay2 Input 1 Relay1 Input Remote Unit 2 8 to 16 VDC In 1 Ground 12 RLY2 N O 11 RLY2 Com 10 RLY2 N C 9 RLY1 N O 8 RLY1 Com 7 RLY1 N...

Страница 12: ...Ground 3 Aux Out 2 Relay2 Input 1 Relay1 Input Remote Unit 2 8 to 16 VDC In 1 Ground 12 RLY2 N O 11 RLY2 Com 10 RLY2 N C 9 RLY1 N O 8 RLY1 Com 7 RLY1 N C 6 RS232 Out 5 RS232 In 4 Ground 3 Aux In 2 N...

Страница 13: ...Ground 3 Aux Out 2 Relay2 Input 1 Relay1 Input Remote Unit 2 8 to 16 VDC In 1 Ground 12 RLY2 N O 11 RLY2 Com 10 RLY2 N C 9 RLY1 N O 8 RLY1 Com 7 RLY1 N C 6 RS232 Out 5 RS232 In 4 Ground 3 Aux In 2 N...

Страница 14: ...C 8 485 7 485 6 5 VDC Out 5 RLY4 Input 5V 4 RLY3 Input 5V 3 LED Output 2 D1 Data F2F Input 1 D0 CLK Input Input Red arrow denotes direction of command signal Relay 3 Input and Output Output Suprex Op...

Страница 15: ...2 In 4 Ground 3 Aux Out 2 Relay2 Input 1 Relay1 Input Remote Unit 2 8 to 16 VDC In 1 Ground 12 RLY2 N O 11 RLY2 Com 10 RLY2 N C 9 RLY1 N O 8 RLY1 Com 7 RLY1 N C 6 RS232 Out 5 RS232 In 4 Ground 3 Aux I...

Страница 16: ...4 Ground 3 Aux Out 2 Relay2 Input 1 Relay1 Input Remote Unit 2 8 to 16 VDC In 1 Ground 12 RLY2 N O 11 RLY2 Com 10 RLY2 N C 9 RLY1 N O 8 RLY1 Com 7 RLY1 N C 6 RS232 Out 5 RS232 In 4 Ground 3 Aux In 2...

Отзывы: