Bench Testing:
Before installing the units in the field they should be assembled and tested at a convenient “Bench
top” location. This will make it easier to verify / change settings and check operation when both
units are visible at the same time.
It is also a chance to become familiar with the system if this is the first time using the Suprex®
system. It is much more difficult to setup and test the units when they are several thousand feet
apart.
1. Connect the Remote and Central unit Network ports together using either a crossover cable or
connect both to a common network hub.
2. Connect a suitable power supply to both units. Each unit should be provided with 8 - 16 volts DC
and a minimum of 500mA.
3. Apply power. After about a 5 - 10 second delay both units Diagnostic LED should indicate Green.
4. Touch a jumper wire from the Ground connection the the Relay 1 input on the Central unit. Relay
#1 on the Remote unit should activate with an audible click and the Diagnostic LEDs should flash
green on both the Central and Remote units.
5. Units are shipped from the factory set for the Wiegand data format. If a different format is required
set the DIP switch to the required reader and panel format.
6. If a reader and panel is accessible, connect the reader to the Remote unit and the Central unit to
the panel and verify that card reads are being accepted by the access control system. If any
troubleshooting is necessary, it will be easier to do with both units in close proximity to each other.
7. Once these steps are completed, the units are ready for installation it their permanent locations
and final commissioning as a system.
Network Addressing:
Each Suprex® SPX-7200 pair is preconfigured with a factory default TCP/IP address.
Suprex® Central = 192.168.49.58
Suprex® Remote = 192.168.49.59
It may be necessary to change these settings to be compatible with the network that will be
used in the final installation. The SPX-7200 system requires the use of fixed IP addresses to be
assigned to the units. It may be necessary to coordinate with the System Administrator before
placing the devices on a network.
The Lantronix Xport Direct Device Installer program can be used. The program can be downloaded
from
www.lantronix.com
under support/downloads/Xport Direct/ Device Installer.
This manual will describe how to change the IP address and net mask for the units using the Xport
Device Installer software. Once the Addresses have been set to be compatible with the network,
final installation can be made.