CY8CKIT-017 CAN/LIN Expansion Board Kit Guide, Doc. # 001-57814 Rev. *D
21
Kit Operation
Figure 3-13. Verify LCD Output of LIN_Example
2. Configure the LIN analyzer/master with checksum set to Enhanced and baud rate set to 19200.
3. Send an unconditional frame having eight bytes of data (Byte 1 is the scalar signal of 7-bit length
and Byte 2 to 8 is byte array signal of 7-byte length) with a frame ID of 0x10 from the LIN ana-
lyzer/master. The frame ID and values of data received are displayed after ‘Recd-Data’ on the
LCD. This data will be displayed for 12 seconds.
Figure 3-14. Received Data Display
4. After 12 seconds, the LCD display changes to ‘Send ID 0x11 to read back data’. Send a frame
with an ID of 0x11 from the LIN analyzer/master.
5. When the frame with ID 0x11 is received, the data is sent to the LIN master. The frame ID and
values of sent data is displayed on the LCD for 12 seconds.