Getting Started with EZ-
PD™ CCG3PA
www.cypress.com
Document No. 002-18179 Rev. **
19
Figure 14. Start Capturing Traffic in EZ-PD Analyzer Utility
8. Connect the MacBook to the Type-C receptacle of the CY4500 EZ-PD Protocol Analyzer (see
) using a
Type-C cable. Observe that the PD traffic is being captured on the EZ-PD Analyzer Utility. The utility running on
the host PC should look similar to that in
Figure 15
.
Connecting CY4500 EZ-PD Protocol Analyzer to CY4532 CCG3PA EVK
MacBook
Header Connection
J1
1-2
J2
2-3
J5
1-2
J3
NC
J6
NC
Host PC
Micro USB Cable
9. A successful PD contract can be seen from the PD message sequence. From
, it is clear that the
Type-C device used in this example is a UFP (Sink/Power Consumer) and the Type-C port of the CY4532
CCG3PA EVK is a DFP (Source/Power Provider). Looking at the
, it can be seen that
the VBUS voltage is still set to 5 V at the end of the power contract negotiation.
Start Capturing