Bluetooth Low Energy Current Consumption Measurements
www.cypress.com
Document No. 002-14934 Rev. *C
19
6. In the HCI Control window, select
7.8: LE Controller Commands (8 key)
from the list.
7. Select
LE_Set_Scan_Parameters
from the menu. Set the scan parameters as below, and click
OK
:
LE_Scan_type:
Passive Scanning
LE_Scan_Interval:
2048
LE_Scan_Window:
18
8. Select
LE_Set_Scan_Enable
from the menu. In the LE_Scan_Enable window, select
Scanning is enabled
,
and click
OK
.