
CY24272
Document Number: 001-42414 Rev. **
Page 7 of 13
DC Operating Conditions
Parameter
Description
Condition
Min
Max
Unit
V
DDP
Supply Voltage for PLL
2.5V ± 5%
2.375
2.625
V
V
DDC
Supply Voltage for Core
2.5V ± 5%
2.375
2.625
V
V
DD
Supply Voltage for Clock Buffers
2.5V ± 5%
2.375
2.625
V
V
IHCLK
Input High Voltage, REFCLK/REFCLKB
0.6
0.95
V
V
ILCLK
Input Low Voltage, REFCLK/REFCLKB
–0.15
+0.15
V
V
IXCLK
[6]
Crossing Point Voltage, REFCLK/REFCLKB
200
550
mV
Δ
V
IXCLK
[6]
Difference in Crossing Point Voltage, REFCLK/REFCLKB
–
150
mV
V
IH
Input Signal High Voltage at ID0, ID1, EN, and /BYPASS
1.4
2.625
V
V
IL
Input Signal Low Voltage at ID0, ID1, EN, and /BYPASS
–0.15
0.8
V
V
IH,SM
Input Signal High Voltage at SCL and SDA
[7]
1.4
3.465
V
V
IL,SM
Input Signal Low Voltage at SCL and SDA
–0.15
0.8
V
V
TH
[8]
Input Threshold Voltage for single-ended REFCLK
0.35
0.5V
DD
V
V
IH,SE
Input Signal High Voltage for single-ended REFCLK
V
TH
+ 0.3
2.625
V
V
IL,SE
Input Signal Low Voltage for single-ended REFCLK
–0.15
V
TH
– 0.3
V
T
A
Ambient Operating Temperature
0
70
°C
Notes
6. Not 100% tested except V
IXCLK
and
Δ
V
IXCLK
. Parameters guaranteed by design and characterizations, not 100% tested in production.
7. This range of SCL and SDA input high voltage enables the CY24272 for use with 3.3V, 2.5V, or 1.8V SMBus voltages.
8. Single-ended operation guaranteed only when 0.8 < (V
IH,SE
– V
TH
)/(V
TH
– V
IL
,
SE
) < 1.2.
[+] Feedback